ACIQ / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 20

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5461 / 461
EER2 · BTU/Wh11.5–14461 / 461
HSPF2 · BTU/Wh7.8–8.5461 / 461
Cooling capacity · BTU/h22,200–25,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000461 / 461
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500461 / 461
COP at 5°F / −15°C1.9–2.24461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X24M12A*+ furnace: *80VTL0701716B*AHRI reference: 21663267416.007.80111001.92EPA 3962429 →
ESH5X24M12A*+ furnace: *96VSN0601412B*AHRI reference: 21663268816.008.00111002.05EPA 3962433 →
ESH5X24M12A*+ furnace: *80VTL0451412B*AHRI reference: 21663267316.007.80110001.94EPA 3962434 →
ESH5X24M12A*+ furnace: *80VSL0451412B*AHRI reference: 21663265416.007.80110001.94EPA 3962435 →
ESH5X24M12A*+ furnace: *80MSU1002120A*AHRI reference: 21663266416.007.80111002.00EPA 3962436 →
ESH5X24M12A*+ furnace: *80VSL0701716B*AHRI reference: 21663265616.008.00111002.05EPA 3962437 →
ESH5X24M12A*+ furnace: *96VTN0801716B*AHRI reference: 21663270916.007.80110001.94EPA 3962438 →
ESH5X24M12A*+ furnace: *96VTN0601716B*AHRI reference: 21663270816.008.00111002.05EPA 3962439 →
ESH5X24M12A*+ furnace: *96VSN0601716B*AHRI reference: 21663268916.008.00111002.05EPA 3962440 →
ESH5X24M12A*+ furnace: *96VSN1202422B*AHRI reference: 21663269316.007.80111001.94EPA 3962441 →
ESH5X24M12A*+ furnace: *96VSN0801716B*AHRI reference: 21663269016.007.80110001.94EPA 3962442 →
ESH5X24M12A*+ furnace: *96VTN0601412B*AHRI reference: 21663270716.008.00111002.05EPA 3962443 →
ESH5X24M12A*+ furnace: *96VSN1002120B*AHRI reference: 21663269216.008.00112002.05EPA 3962444 →
ESH5X24M12A*+ furnace: *96VTN1002120B*AHRI reference: 21663271116.007.80111001.94EPA 3962445 →
ESH5X30M12A*+ furnace: *80CSU0401712A*AHRI reference: 21663271716.007.80112002.06EPA 3962447 →
ESH5X24M12A*+ furnace: *96VTN1202422B*AHRI reference: 21663271316.008.00111002.05EPA 3962452 →
ESH5X30M12A*+ furnace: *80VSL1352422B*AHRI reference: 21663272416.007.80110002.08EPA 3962454 →
ESH5X30M12A*+ furnace: *80MSU1002120A*AHRI reference: 21663272816.008.00112002.10EPA 3962456 →
ESH5X30M12A*+ furnace: *80CTL1352422B*AHRI reference: 21663273616.007.80110002.08EPA 3962461 →
ESH5X30M12A*+ furnace: *80CTL0902120B*AHRI reference: 21663273416.007.80110002.08EPA 3962464 →