ACIQ / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 17

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5461 / 461
EER2 · BTU/Wh11.5–14461 / 461
HSPF2 · BTU/Wh7.8–8.5461 / 461
Cooling capacity · BTU/h22,200–25,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000461 / 461
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500461 / 461
COP at 5°F / −15°C1.9–2.24461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X36M12A*+ furnace: *80VSL0451412B*AHRI reference: 21663278216.507.80109001.96EPA 3962510 →
ESH5X36M12A*+ furnace: *80VSL0901716B*AHRI reference: 21663278516.507.80110001.96EPA 3962511 →
ESH5X36M12A*+ furnace: *80MSU0601716A*AHRI reference: 21663279016.507.80109002.10EPA 3962512 →
ESH5X36M12A*+ furnace: *80VTL0451412B*AHRI reference: 21663280116.507.80109001.96EPA 3962513 →
ESH5X36M12A*+ furnace: *80CTL1352422B*AHRI reference: 21663280016.507.80110002.08EPA 3962515 →
ESH5X36M12A*+ furnace: *80MSU0401712A*AHRI reference: 21663278916.507.80110002.08EPA 3962517 →
ESH5X36M12A*+ furnace: *80VTL0701716B*AHRI reference: 21663280216.507.80110001.96EPA 3962518 →
ESH5X36M12A*+ furnace: *80CTL0902120B*AHRI reference: 21663279816.507.80110002.08EPA 3962519 →
ESH5X36M12A*+ furnace: *96VSN0802120B*AHRI reference: 21663281916.507.80109001.96EPA 3962520 →
ESH5X36M12A*+ furnace: *96VSN1002120B*AHRI reference: 21663282016.508.00110002.08EPA 3962521 →
ESH5X36M12A*+ furnace: *96VSN0601716B*AHRI reference: 21663281716.507.80110001.96EPA 3962522 →
ESH5X36M12A*+ furnace: *80VTL0902120B*AHRI reference: 21663280316.507.80110002.08EPA 3962523 →
ESH5X36M12A*+ furnace: *95CSU1002122B*AHRI reference: 21663280716.507.80110002.08EPA 3962524 →
ESH5X36M12A*+ furnace: *97CMN0802120B*AHRI reference: 21663281116.507.80110002.08EPA 3962525 →
ESH5X36M12A*+ furnace: *97CMN1002122B*AHRI reference: 21663281216.507.80109002.08EPA 3962527 →
ESH5X36M12A*+ furnace: *95MSU0802120A*AHRI reference: 21663282416.507.80110002.08EPA 3962529 →
ESH5X36M12A*+ furnace: *96VTN0802120B*AHRI reference: 21663283716.507.80109001.96EPA 3962532 →
ESH5X36M12A*+ furnace: *96VTN1002120B*AHRI reference: 21663283816.507.80110002.08EPA 3962533 →
ESH5X36M12A*+ furnace: *96VTN1202422B*AHRI reference: 21663284016.507.80110001.96EPA 3962534 →
ESH5X36M12A*+ furnace: *96VTN0601716B*AHRI reference: 21663283516.507.80110001.96EPA 3962536 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →