ACIQ / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 15

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5461 / 461
EER2 · BTU/Wh11.5–14461 / 461
HSPF2 · BTU/Wh7.8–8.5461 / 461
Cooling capacity · BTU/h22,200–25,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000461 / 461
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500461 / 461
COP at 5°F / −15°C1.9–2.24461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M17A*+ furnace: *96VSN0401712B*AHRI reference: 21663258716.508.10113002.04EPA 3962345
EA*5X37M17A*+ furnace: *96VSN0401410B*AHRI reference: 21663258616.508.10112002.04EPA 3962348
EA*5X37M17A*+ furnace: *96VTN0401712B*AHRI reference: 21663259716.508.10113002.04EPA 3962353
EA*5X37M17A*+ furnace: *96VTN0401410B*AHRI reference: 21663259616.508.10114002.04EPA 3962355
ESH5X24M12A*+ furnace: *96VTN1002122B*AHRI reference: 21663271216.507.80110001.94EPA 3962446
ESH5X30M12A*+ furnace: *80VSL0701412B*AHRI reference: 21663271916.508.00111002.08EPA 3962448
ESH5X30M12A*+ furnace: *80VSL0902120B*AHRI reference: 21663272216.508.00112002.06EPA 3962449
ESH5X30M12A*+ furnace: *80VSL0451412B*AHRI reference: 21663271816.507.80111002.08EPA 3962450
ESH5X30M12A*+ furnace: *80VSL0901716B*AHRI reference: 21663272116.507.80110002.08EPA 3962451
ESH5X30M12A*+ furnace: *80VSL0701716B*AHRI reference: 21663272016.507.80111002.08EPA 3962453
ESH5X30M12A*+ furnace: *80MSU0802120A*AHRI reference: 21663272716.507.80110002.08EPA 3962455
ESH5X30M12A*+ furnace: *80VSL1102122B*AHRI reference: 21663272316.508.00110002.08EPA 3962457
ESH5X30M12A*+ furnace: *80CTL0701412B*AHRI reference: 21663273016.508.00110002.06EPA 3962458
ESH5X30M12A*+ furnace: *80MSU0401712A*AHRI reference: 21663272516.508.00110002.08EPA 3962459
ESH5X30M12A*+ furnace: *80MSU0601716A*AHRI reference: 21663272616.507.80111002.08EPA 3962460
ESH5X30M12A*+ furnace: *80VTL0451412B*AHRI reference: 21663273716.507.80111002.08EPA 3962462
ESH5X30M12A*+ furnace: *80VTL0701716B*AHRI reference: 21663273816.507.80110002.08EPA 3962463
ESH5X30M12A*+ furnace: *80CTL0701716B*AHRI reference: 21663273116.507.80110002.08EPA 3962465
ESH5X30M12A*+ furnace: *80CTL0901716B*AHRI reference: 21663273316.507.80110002.08EPA 3962468
ESH5X30M12A*+ furnace: *80VTL1102122B*AHRI reference: 21663274016.508.00111002.06EPA 3962470

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.