ACIQ / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 13

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5461 / 461
EER2 · BTU/Wh11.5–14461 / 461
HSPF2 · BTU/Wh7.8–8.5461 / 461
Cooling capacity · BTU/h22,200–25,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000461 / 461
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500461 / 461
COP at 5°F / −15°C1.9–2.24461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X24M17A*+ furnace: *80CTL0451712B*AHRI reference: 21663243216.508.10112002.02EPA 3961981 →
EA*5X24M17A*+ furnace: *80CTL0701716B*AHRI reference: 21663243416.508.10110002.04EPA 3961982 →
EA*5X24M17A*+ furnace: *80CTL0901716B*AHRI reference: 21663243516.508.10110002.04EPA 3961983 →
EA*5X24M17A*+ furnace: *95CSU0601716B*AHRI reference: 21663243816.508.00111002.05EPA 3961987 →
EA*5X24M17A*+ furnace: *97CMN0801714B*AHRI reference: 21663244016.508.10111002.04EPA 3961988 →
EA*5X24M17A*+ furnace: *80VTL0701716B*AHRI reference: 21663243716.508.10110002.04EPA 3961989 →
EA*5X24M17A*+ furnace: *80VTL0451412B*AHRI reference: 21663243616.508.10110002.04EPA 3961990 →
EA*5X24M17A*+ furnace: *97CMN0601714B*AHRI reference: 21663243916.508.10111002.04EPA 3961991 →
EA*5X24M17A*+ furnace: *96VSN0801716B*AHRI reference: 21663244516.508.10110002.04EPA 3961992 →
EA*5X24M17A*+ furnace: *95MSU0601716A*AHRI reference: 21663244716.507.80110002.04EPA 3961993 →
EA*5X24M17A*+ furnace: *95MSU0401712A*AHRI reference: 21663244616.507.80111002.02EPA 3961994 →
EA*5X24M17A*+ furnace: *96VSN0601716B*AHRI reference: 21663244416.508.10110002.04EPA 3961995 →
EA*5X24M17A*+ furnace: *96VTN0601716B*AHRI reference: 21663245416.508.10110002.04EPA 3961996 →
EA*5X24M17A*+ furnace: *96CTN0601714B*AHRI reference: 21663244916.508.10111002.04EPA 3961997 →
EA*5X24M17A*+ furnace: *96CTN0801714B*AHRI reference: 21663245016.508.10111002.04EPA 3961998 →
EA*5X24M17A*+ furnace: OMV112K14AAHRI reference: 21663245816.508.10112002.00EPA 3962004 →
EA*5X24M17A*+ furnace: *96VTN0801716B*AHRI reference: 21663245516.508.10110002.04EPA 3962005 →
EA*5X25M17A*+ furnace: *96VSN0401410B*AHRI reference: 21663247516.508.10113002.06EPA 3962023 →
EA*5X25M17A*+ furnace: *96CTN0401410B*AHRI reference: 21663248216.508.10113002.06EPA 3962029 →
EA*5X25M17A*+ furnace: *96VSN0401712B*AHRI reference: 21663247616.508.10113002.08EPA 3962031 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →