ACIQ / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 11

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5461 / 461
EER2 · BTU/Wh11.5–14461 / 461
HSPF2 · BTU/Wh7.8–8.5461 / 461
Cooling capacity · BTU/h22,200–25,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h24,000–25,400461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h14,100–15,000461 / 461
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500461 / 461
COP at 5°F / −15°C1.9–2.24461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X37M21A*+ furnace: *96VSN0401712B*AHRI reference: 21663263017.008.10114002.06EPA 3962394
EA*5X37M21A*+ furnace: *96VTN0401712B*AHRI reference: 21663264417.008.10114002.06EPA 3962402
EA*5X37M21A*+ furnace: OLV098A12*AHRI reference: 21663265017.008.10115002.04EPA 3962412
ESH5X36M12A*+ furnace: *80VSL1102122B*AHRI reference: 21663278717.007.80110002.08EPA 3962505
ESH5X36M12A*+ furnace: *80CSU0401712A*AHRI reference: 21663278117.008.10111002.08EPA 3962507
ESH5X36M12A*+ furnace: *80MSU0802120A*AHRI reference: 21663279117.007.80110002.10EPA 3962514
ESH5X36M12A*+ furnace: *80CTL0701412B*AHRI reference: 21663279417.007.80110002.08EPA 3962516
ESH5X36M12A*+ furnace: *80VTL1102122B*AHRI reference: 21663280417.007.80111002.08EPA 3962526
ESH5X36M12A*+ furnace: *95MSU1002120A*AHRI reference: 21663282517.007.80110002.08EPA 3962528
ESH5X36M12A*+ furnace: *96VSN1202422B*AHRI reference: 21663282117.008.00110002.08EPA 3962530
ESH5X36M12A*+ furnace: *95MSU1002122A*AHRI reference: 21663282617.007.80110002.08EPA 3962531
ESH5X36M12A*+ furnace: *96VTN1002122B*AHRI reference: 21663283917.007.80109002.10EPA 3962539
EA*5X25M17A*+ furnace: *80CSU0401712B*AHRI reference: 21663506717.008.00110002.10EPA 3964769
EA*5X25M17A*+ furnace: *97CTN0601716A*AHRI reference: 21663506917.008.00111002.08EPA 3964771
EA*5X30M17A*+ furnace: *97VTN0801716A*AHRI reference: 21663507817.008.00110002.06EPA 3964774
EA*5X36M17A*+ furnace: *97CTN0801716A*AHRI reference: 21663508217.008.00110002.06EPA 3964775
EA*5X36M17A*+ furnace: *80CSU0401712B*AHRI reference: 21663507917.008.00109002.06EPA 3964776
EA*5X36M17A*+ furnace: *97VTN0601716A*AHRI reference: 21663508317.008.00110002.06EPA 3964778
EA*5X30M17A*+ furnace: *97CTN0801716A*AHRI reference: 21663507617.008.00110002.06EPA 3964779
EA*5X36M17A*+ furnace: *80CSU0601716B*AHRI reference: 21663508017.007.80109002.08EPA 3964782

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.