ACIQ / AIR-SOURCE HEAT PUMP

N5H5S24*K*AAA*

PERFORMANCE 16 SEER2 HP

182 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–24,400BTU/h

Each efficiency range summarizes published EPA records for N5H5S24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 182 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5182 / 182
EER2 · BTU/Wh11.7–13182 / 182
HSPF2 · BTU/Wh7.8–8.5182 / 182
Cooling capacity · BTU/h22,200–24,400182 / 182
Heating capacity at 47°F / 8.3°C · BTU/h21,600–24,000182 / 182
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,200182 / 182
Heating capacity at 5°F / −15°C · BTU/h10,800–11,900182 / 182
COP at 5°F / −15°C1.96–2.26182 / 182
Equipment / loop typeHP - Split System182 / 182
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)182 / 182
Compressor stagingSingle stage182 / 182
Connected capabilityNo182 / 182

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
FMA5X30**AL*AHRI reference: 21663061516.508.50116002.26EPA 3960503 →
EA*5X37M21A*+ furnace: *97VTN1002120A*AHRI reference: 21581801816.008.00115002.10EPA 3653681 →
EA*5X37M21A*+ furnace: *97VTN1002122A*AHRI reference: 21581802016.008.00114002.10EPA 3653683 →
EA*5X37M21A*+ furnace: *96CTN0802120B*AHRI reference: 21587130416.007.80114001.96EPA 3720010 →
EVD5X31M17A*+ furnace: *80VSL0901716B*AHRI reference: 21663013316.007.80113001.98EPA 3960303 →
EA*5X25M17A*+ furnace: *80MSU0401712A*AHRI reference: 21663038316.007.80113002.12EPA 3960395 →
EA*5X25M17A*+ furnace: *80MSU0601716A*AHRI reference: 21663038516.007.80112002.12EPA 3960397 →
EA*5X25M17A*+ furnace: *80CTL0701412B*AHRI reference: 21663038716.007.80114002.12EPA 3960400 →
EA*5X37M21A*+ furnace: *80CSU0401712A*AHRI reference: 21663039516.007.80112002.12EPA 3960406 →
EA*5X37M21A*+ furnace: *80CSU0802120A*AHRI reference: 21663039716.007.80113002.14EPA 3960407 →
EA*5X37M21A*+ furnace: *80CTL0902120B*AHRI reference: 21663041916.007.80115002.14EPA 3960418 →
EA*5X37M21A*+ furnace: *80VTL1102122B*AHRI reference: 21663042116.007.80115002.14EPA 3960419 →
EA*5X37M21A*+ furnace: *95CSU1002122B*AHRI reference: 21663042316.007.80116002.14EPA 3960423 →
EA*5X37M21A*+ furnace: *97CMN1002122B*AHRI reference: 21663042716.007.80115002.14EPA 3960428 →
EA*5X37M21A*+ furnace: *97CMN0802120B*AHRI reference: 21663042516.007.80115002.14EPA 3960429 →
EA*5X37M21A*+ furnace: *95MSU1002120A*AHRI reference: 21663044116.007.80115002.14EPA 3960443 →
EA*5X37M21A*+ furnace: *96CTN1002122B*AHRI reference: 21663044516.007.80115002.14EPA 3960446 →
EVM5X31M17A*+ furnace: *80MSU0601716A*AHRI reference: 21663045916.007.80112001.98EPA 3960454 →
EVM5X32M17A*+ furnace: *80MS(N,L)0901714A*AHRI reference: 21663046716.007.80112001.98EPA 3960457 →
EVM5X32M17A*+ furnace: *80MSU0601716A*AHRI reference: 21663047916.007.80113002.00EPA 3960458 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →