ACIQ / AIR-SOURCE HEAT PUMP

H5H3V48*K*AAA*

Deluxe 23 VS Heat Pump · source records, page 7

125 published source records · source checked Sep 21, 2026

SEER2 range19.5–23BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity43,000–46,500BTU/h

Each efficiency range summarizes published EPA records for H5H3V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 125 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh19.5–23125 / 125
EER2 · BTU/Wh10–12.5125 / 125
HSPF2 · BTU/Wh8–9.5125 / 125
Cooling capacity · BTU/h43,000–46,500125 / 125
Heating capacity at 47°F / 8.3°C · BTU/h48,000–53,500125 / 125
Heating capacity at 17°F / −8.3°C · BTU/h39,000–43,500125 / 125
Heating capacity at 5°F / −15°C · BTU/h35,600–38,500125 / 125
COP at 5°F / −15°C1.8–2125 / 125
Equipment / loop typeHP - Split System125 / 125
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)125 / 125
Compressor stagingContinuously variable125 / 125
Connected capabilityNo125 / 125

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X48M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21663624020.008.10380001.90EPA 3966082
EVD5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21663623920.008.10385002.00EPA 3966083
EVD5X48M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21663624220.008.10380001.90EPA 3966088
EVM5X48M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21663620819.508.10385001.90EPA 3966077
EVD5X48M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21663623419.508.10385001.90EPA 3966085

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →