SEER2 range18–22.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,000–36,000BTU/h

Each efficiency range summarizes published EPA records for H5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–22.5564 / 564
EER2 · BTU/Wh10–13564 / 564
HSPF2 · BTU/Wh8.1–9.5564 / 564
Cooling capacity · BTU/h32,000–36,000564 / 564
Heating capacity at 47°F / 8.3°C · BTU/h33,400–39,500564 / 564
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,800564 / 564
Heating capacity at 5°F / −15°C · BTU/h25,200–29,600564 / 564
COP at 5°F / −15°C1.88–2.14564 / 564
Equipment / loop typeHP - Split System564 / 564
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)564 / 564
Compressor stagingContinuously variable564 / 564
Connected capabilityNo564 / 564

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X60M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21663560021.508.50290002.02EPA 3965528
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21663559821.508.50288002.02EPA 3965529
EVM5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21663560621.508.50286002.04EPA 3965534
EVM5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21663560521.508.50290002.02EPA 3965535
EVM5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21663560121.508.50286002.02EPA 3965537
EVM5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21663560921.508.50290002.02EPA 3965538
EVM5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21663561021.508.50286002.02EPA 3965539
EVM5X60M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 21663561421.508.50286002.02EPA 3965540
EVM5X60M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 21663561221.508.50288002.02EPA 3965541
EVM5X60M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21663562221.508.50284002.04EPA 3965545
EVM5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21663561521.508.50286002.04EPA 3965547
EVM5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21663561921.508.50286002.04EPA 3965548
EVM5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21663563121.508.50286002.06EPA 3965552
EVD5X60M21A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 21663574121.508.50288002.02EPA 3965649
EVD5X60M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 21663574621.508.50290002.02EPA 3965650
EVD5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 21663574221.508.50286002.04EPA 3965651
EVD5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 21663574721.508.50286002.04EPA 3965652
EVD5X60M21A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 21663575321.508.50288002.02EPA 3965655
EVD5X60M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 21663575021.508.50290002.02EPA 3965657