H5H3V36*K*AAA*
Deluxe 23 VS Heat Pump · source records, page 15
564 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 564 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 564 / 564 |
| EER2 · BTU/Wh | 10–13 | 564 / 564 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 564 / 564 |
| Cooling capacity · BTU/h | 32,000–36,000 | 564 / 564 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 564 / 564 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 564 / 564 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 564 / 564 |
| COP at 5°F / −15°C | 1.88–2.14 | 564 / 564 |
| Equipment / loop type | HP - Split System | 564 / 564 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 564 / 564 |
| Compressor staging | Continuously variable | 564 / 564 |
| Connected capability | No | 564 / 564 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X60M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 216635345 | 20.50 | 9.50 | 25800 | 2.06 | EPA 3965021 → |
EA*5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 216635343 | 20.50 | 9.50 | 25800 | 2.06 | EPA 3965022 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 216635348 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965025 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0401712A*Cold climate designationAHRI reference: 216635347 | 20.50 | 9.00 | 26200 | 1.94 | EPA 3965027 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 216635352 | 20.50 | 9.00 | 26200 | 1.96 | EPA 3965028 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 216635354 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965029 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 216635353 | 20.50 | 9.00 | 26200 | 1.96 | EPA 3965030 → |
EA*5X61M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 216635358 | 20.50 | 9.50 | 26000 | 2.08 | EPA 3965035 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 216635355 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965036 → |
EA*5X61M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 216635362 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965038 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 216635369 | 20.50 | 9.50 | 25800 | 2.06 | EPA 3965040 → |
EA*5X61M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 216635370 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965041 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 216635368 | 20.50 | 9.50 | 25800 | 2.06 | EPA 3965042 → |
EA*5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 216635371 | 20.50 | 9.50 | 25800 | 2.06 | EPA 3965043 → |
EA*5X61M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 216635367 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965044 → |
EA*5X61M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 216635365 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965046 → |
EA*5X61M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 216635366 | 20.50 | 9.00 | 26200 | 1.96 | EPA 3965047 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 216635374 | 20.50 | 9.50 | 26000 | 2.08 | EPA 3965050 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 216635375 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965051 → |
EA*5X61M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 216635373 | 20.50 | 9.50 | 26000 | 2.06 | EPA 3965052 → |