Heating performance & equipment details
Ranges include the 158 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16.5–19 | 158 / 158 |
| EER2 · BTU/Wh | 8–9.8 | 158 / 158 |
| HSPF2 · BTU/Wh | 8.1–9 | 158 / 158 |
| Cooling capacity · BTU/h | 54,000–58,000 | 158 / 158 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–63,500 | 54 / 158 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 50,500–57,500 | 158 / 158 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–46,000 | 158 / 158 |
| COP at 5°F / −15°C | 1.86–2.1 | 158 / 158 |
| Equipment / loop type | HP - Split System | 158 / 158 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 158 / 158 |
| Compressor staging | Continuously variable | 158 / 158 |
| Connected capability | No | 158 / 158 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 216634596 | 18.50 | 9.00 | 42000 | 1.90 | EPA 3964697 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634597 | 18.50 | 9.00 | 41500 | 1.90 | EPA 3964698 → |
EA*5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 216634598 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3964699 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 216634594 | 18.50 | 8.50 | 41000 | 2.04 | EPA 3964701 → |
EA*5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 216634601 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3964703 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 216634604 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3964704 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 216634606 | 18.50 | 9.00 | 41500 | 2.02 | EPA 3964705 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634605 | 18.50 | 9.00 | 42000 | 2.02 | EPA 3964709 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634621 | 18.50 | 9.00 | 45000 | 2.08 | EPA 3964714 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 216634038 | 18.00 | 9.00 | 45000 | 2.06 | EPA 3963824 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 216634032 | 18.00 | 9.00 | 44500 | 2.08 | EPA 3963825 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 216634033 | 18.00 | 9.00 | 45000 | 2.08 | EPA 3963826 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 216634035 | 18.00 | 9.00 | 45000 | 2.06 | EPA 3963830 → |
EVM5X60M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 216634039 | 18.00 | 9.00 | 44500 | 2.08 | EPA 3963831 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 216634046 | 18.00 | 9.00 | 45000 | 2.06 | EPA 3963834 → |
EVM5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 216634041 | 18.00 | 9.00 | 45000 | 2.06 | EPA 3963835 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU1002120A*Cold climate designationAHRI reference: 216634045 | 18.00 | 9.00 | 44500 | 2.08 | EPA 3963836 → |
EVM5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 216634050 | 18.00 | 9.00 | 44500 | 2.08 | EPA 3963839 → |
EVM5X60M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 216634051 | 18.00 | 9.00 | 44000 | 2.08 | EPA 3963842 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 216634062 | 18.00 | 9.00 | 45500 | 2.06 | EPA 3963848 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.