| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634543 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3964562 → |
EVM5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 216634544 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3964580 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 216634592 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3964690 → |
EVD5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634591 | 19.50 | 9.50 | 36600 | 2.12 | EPA 3964691 → |
EVD5X61M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634586 | 19.50 | 9.50 | 36800 | 2.12 | EPA 3964694 → |
FCMA5B48L0C*+WALLCONCold climate designationAHRI reference: 216632847 | 19.00 | 9.00 | 33600 | 2.10 | EPA 3962566 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 216633886 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3963470 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0601716A*Cold climate designationAHRI reference: 216633885 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3963472 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 216633893 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3963478 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 216633892 | 19.00 | 9.00 | 36600 | 2.00 | EPA 3963480 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 216633890 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3963481 → |
EVM5X49M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 216633891 | 19.00 | 9.00 | 37000 | 1.98 | EPA 3963484 → |
EVM5X49M21A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 216633899 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3963487 → |
EVM5X49M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 216633895 | 19.00 | 9.00 | 36600 | 2.02 | EPA 3963489 → |
EVM5X49M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 216633898 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3963490 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 216633909 | 19.00 | 9.50 | 36600 | 2.10 | EPA 3963493 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 216633908 | 19.00 | 9.00 | 37000 | 1.98 | EPA 3963494 → |
EVM5X49M21A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 216633901 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3963495 → |
EVM5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 216633907 | 19.00 | 9.00 | 36800 | 2.00 | EPA 3963496 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 216633903 | 19.00 | 9.00 | 36600 | 2.12 | EPA 3963498 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →