| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X48M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 216634471 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3964424 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 216634481 | 17.50 | 9.00 | 33800 | 2.08 | EPA 3964432 → |
EA*5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 216634475 | 17.50 | 9.00 | 33600 | 2.06 | EPA 3964434 → |
EA*5X61M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 216634484 | 17.50 | 9.00 | 34200 | 2.06 | EPA 3964443 → |
EA*5X61M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 216634483 | 17.50 | 9.00 | 33600 | 2.06 | EPA 3964445 → |
EA*5X48M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 216633768 | 17.00 | 9.00 | 35000 | 2.02 | EPA 3963373 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0801714B*Cold climate designationAHRI reference: 216633777 | 17.00 | 9.00 | 34600 | 2.04 | EPA 3963376 → |
EA*5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 216633776 | 17.00 | 9.00 | 34600 | 2.04 | EPA 3963378 → |
EA*5X48M21A*+WALLCON+ furnace: *95CSU0601716B*Cold climate designationAHRI reference: 216633774 | 17.00 | 9.00 | 34600 | 2.04 | EPA 3963382 → |
EA*5X61M21A*+WALLCON+ furnace: *80CTL0451712B*Cold climate designationAHRI reference: 216633799 | 17.00 | 9.00 | 34600 | 2.06 | EPA 3963406 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 216633849 | 17.00 | 8.50 | 33600 | 2.08 | EPA 3963439 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 216634469 | 17.00 | 9.00 | 34000 | 2.04 | EPA 3964421 → |
EA*5X48M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 216634470 | 17.00 | 9.00 | 34600 | 2.04 | EPA 3964422 → |
EA*5X48M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 216634467 | 17.00 | 9.00 | 34200 | 2.04 | EPA 3964425 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 216634504 | 17.00 | 8.50 | 33800 | 2.08 | EPA 3964444 → |
ESH5X60M12A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 216634505 | 17.00 | 8.50 | 33600 | 2.06 | EPA 3964454 → |
ESH5X48M12A*+WALLCON+ furnace: *80CSU0802120A*Cold climate designationAHRI reference: 216633827 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3963429 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 216633834 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3963431 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 216633836 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3963432 → |
ESH5X48M12A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 216633835 | 16.50 | 8.50 | 34200 | 2.06 | EPA 3963433 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →