H5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 11
376 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for H5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 376 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 376 / 376 |
| EER2 · BTU/Wh | 9–10.5 | 376 / 376 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 376 / 376 |
| Cooling capacity · BTU/h | 43,500–49,000 | 376 / 376 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 376 / 376 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 376 / 376 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 376 / 376 |
| COP at 5°F / −15°C | 1.92–2.2 | 376 / 376 |
| Equipment / loop type | HP - Split System | 376 / 376 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 376 / 376 |
| Compressor staging | Continuously variable | 376 / 376 |
| Connected capability | No | 376 / 376 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X61M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634491 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3964440 → |
EA*5X61M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 216634492 | 18.50 | 9.00 | 33600 | 2.06 | EPA 3964447 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 216634519 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3964463 → |
EVM5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634516 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3964464 → |
EVM5X48M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 216634513 | 18.50 | 9.00 | 36200 | 2.00 | EPA 3964538 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 216634518 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3964539 → |
EVM5X49M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 216634522 | 18.50 | 9.00 | 37200 | 1.98 | EPA 3964541 → |
EVM5X49M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 216634521 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3964545 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 216634527 | 18.50 | 9.00 | 36800 | 2.00 | EPA 3964546 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 216634526 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3964547 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 216634535 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3964552 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0801716A*Cold climate designationAHRI reference: 216634530 | 18.50 | 9.00 | 37200 | 1.98 | EPA 3964553 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 216634529 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3964554 → |
EVD5X48M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 216634551 | 18.50 | 9.00 | 36600 | 1.98 | EPA 3964574 → |
EVD5X48M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 216634545 | 18.50 | 9.00 | 36600 | 1.98 | EPA 3964576 → |
EVD5X48M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 216634552 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3964579 → |
EVD5X48M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 216634548 | 18.50 | 9.00 | 36200 | 2.02 | EPA 3964581 → |
EVD5X48M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 216634554 | 18.50 | 9.00 | 36000 | 2.02 | EPA 3964586 → |
EVD5X49M24A*+WALLCON+ furnace: *80CSU1002120B*Cold climate designationAHRI reference: 216634561 | 18.50 | 9.00 | 36600 | 2.00 | EPA 3964589 → |
EVD5X48M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 216634556 | 18.50 | 9.00 | 36400 | 2.00 | EPA 3964594 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.