ACIQ / AIR-SOURCE HEAT PUMP

B5H3V48*K*AAA*

Deluxe 23 VS Heat Pump · source records, page 4

72 published source records · source checked Sep 21, 2026

SEER2 range20–23BTU/Wh
HSPF2 range9–9.5BTU/Wh
Cooling capacity43,000–46,500BTU/h

Each efficiency range summarizes published EPA records for B5H3V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 72 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh20–2372 / 72
EER2 · BTU/Wh10–12.572 / 72
HSPF2 · BTU/Wh9–9.572 / 72
Cooling capacity · BTU/h43,000–46,50072 / 72
Heating capacity at 47°F / 8.3°C · BTU/h48,000–49,00072 / 72
Heating capacity at 17°F / −8.3°C · BTU/h39,000–40,50072 / 72
Heating capacity at 5°F / −15°C · BTU/h35,600–37,40072 / 72
COP at 5°F / −15°C1.84–272 / 72
Equipment / loop typeHP - Split System72 / 72
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)72 / 72
Compressor stagingContinuously variable72 / 72
Connected capabilityNo72 / 72

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X48M12A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21862974320.009.00364001.88EPA 4659968
ESH5X48M12A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21862974220.009.00364001.88EPA 4659969
ESH5X48M12A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 21862974120.009.00366001.86EPA 4659970
ESH5X48M12A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21862973920.009.00364001.88EPA 4659972
ESH5X48M12A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21862973820.009.00364001.88EPA 4659973
ESH5X48M12A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 21862973720.009.00366001.86EPA 4659974
ESH5X48M12A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21862973520.009.00366001.88EPA 4659976
ESH5X48M12A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21862973420.009.00364001.88EPA 4659977
ESH5X48M12A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 21862973320.009.00366001.86EPA 4659978
ESH5X48M12A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21862972720.009.00366001.86EPA 4659984
ESH5X48M12A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21862972620.009.00366001.88EPA 4659985
EA*5X48M21A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 21862967320.009.00372001.86EPA 4660038

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →