B5H3V36*K*AAA*
Deluxe 23 VS Heat Pump · source records, page 8
514 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18–22.5 | 514 / 514 |
| EER2 · BTU/Wh | 10–12.5 | 514 / 514 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 514 / 514 |
| Cooling capacity · BTU/h | 32,000–36,000 | 514 / 514 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 33,400–39,500 | 514 / 514 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–34,800 | 514 / 514 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,200–29,600 | 514 / 514 |
| COP at 5°F / −15°C | 1.92–2.1 | 514 / 514 |
| Equipment / loop type | HP - Split System | 514 / 514 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 514 / 514 |
| Compressor staging | Continuously variable | 514 / 514 |
| Connected capability | No | 514 / 514 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVD5X48M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218629584 | 21.50 | 8.50 | 28200 | 2.06 | EPA 4660127 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218629583 | 21.50 | 8.50 | 28200 | 2.06 | EPA 4660128 → |
EVD5X48M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218629582 | 21.50 | 8.50 | 28400 | 2.06 | EPA 4660129 → |
EVD5X42M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218629577 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660134 → |
EVD5X42M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218629574 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660137 → |
EVD5X42M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218629571 | 21.50 | 8.50 | 28400 | 2.06 | EPA 4660140 → |
EVD5X42M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218629568 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660143 → |
EVD5X42M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218629564 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660147 → |
EVD5X38M17A*+WALLCON+ furnace: *96CTN0801714B*Cold climate designationAHRI reference: 218629535 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4660176 → |
EVD5X38M17A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218629530 | 21.50 | 8.50 | 28800 | 2.04 | EPA 4660181 → |
EVD5X38M17A*+WALLCON+ furnace: *80CTL0701716B*Cold climate designationAHRI reference: 218629529 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4660182 → |
EVD5X38M17A*+WALLCON+ furnace: *80CTL0701412B*Cold climate designationAHRI reference: 218629528 | 21.50 | 8.50 | 29000 | 2.04 | EPA 4660183 → |
EVM5X61M24A*+WALLCON+ furnace: *97CMN0602120B*Cold climate designationAHRI reference: 218629496 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660215 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218629489 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660222 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218629486 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660225 → |
EVM5X60M24A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218629483 | 21.50 | 8.50 | 28400 | 2.06 | EPA 4660228 → |
EVM5X60M24A*+WALLCON+ furnace: *95CSU0802120B*Cold climate designationAHRI reference: 218629480 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660231 → |
EVM5X60M24A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218629476 | 21.50 | 8.50 | 28600 | 2.06 | EPA 4660235 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218629474 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4660237 → |
EVM5X60M21A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218629470 | 21.50 | 8.50 | 28600 | 2.04 | EPA 4660241 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →