ACIQ / AIR-SOURCE HEAT PUMP

B5H3V36*K*AAA*

Deluxe 23 VS Heat Pump · source records, page 4

514 published source records · source checked Sep 21, 2026

SEER2 range18–22.5BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity32,000–36,000BTU/h

Each efficiency range summarizes published EPA records for B5H3V36*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 514 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh18–22.5514 / 514
EER2 · BTU/Wh10–12.5514 / 514
HSPF2 · BTU/Wh8.1–9.5514 / 514
Cooling capacity · BTU/h32,000–36,000514 / 514
Heating capacity at 47°F / 8.3°C · BTU/h33,400–39,500514 / 514
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,800514 / 514
Heating capacity at 5°F / −15°C · BTU/h25,200–29,600514 / 514
COP at 5°F / −15°C1.92–2.1514 / 514
Equipment / loop typeHP - Split System514 / 514
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)514 / 514
Compressor stagingContinuously variable514 / 514
Connected capabilityNo514 / 514

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X42M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21862957522.008.50284002.06EPA 4660136
EVD5X42M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21862957322.008.50284002.06EPA 4660138
EVD5X42M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21862957222.008.50284002.06EPA 4660139
EVD5X42M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21862956922.008.50284002.06EPA 4660142
EVD5X42M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21862956722.008.50284002.04EPA 4660144
EVD5X42M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21862956622.008.50284002.04EPA 4660145
EVD5X42M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21862956522.008.50284002.04EPA 4660146
EVD5X38M17A*+WALLCON+ furnace: *80CSU0601716B*Cold climate designationAHRI reference: 21862952622.008.50286002.04EPA 4660185
EVD5X38M17A*+WALLCON+ furnace: *80CSU0401712B*Cold climate designationAHRI reference: 21862952522.008.50286002.06EPA 4660186
EVM5X61M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21862949522.008.50282002.06EPA 4660216
EVM5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 21862949122.008.50284002.06EPA 4660220
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 21862949022.008.50284002.06EPA 4660221
EVM5X60M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 21862948822.008.50284002.06EPA 4660223
EVM5X60M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 21862948722.008.50284002.06EPA 4660224
EVM5X60M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 21862948522.008.50284002.06EPA 4660226
EVM5X60M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 21862948422.008.50284002.06EPA 4660227
EVM5X60M24A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 21862948122.008.50284002.06EPA 4660230
EVM5X60M24A*+WALLCON+ furnace: *80CTL1352422B*Cold climate designationAHRI reference: 21862947922.008.50284002.04EPA 4660232
EVM5X60M24A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 21862947822.008.50284002.04EPA 4660233
EVM5X60M24A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 21862947722.008.50284002.04EPA 4660234