B5H0V48*K*AAA*
Deluxe 20 VS Heat Pump · source records, page 6
336 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for B5H0V48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 336 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–19.5 | 336 / 336 |
| EER2 · BTU/Wh | 9–10.5 | 336 / 336 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 336 / 336 |
| Cooling capacity · BTU/h | 43,500–49,000 | 336 / 336 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 47,000–50,000 | 336 / 336 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 41,000–47,500 | 336 / 336 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,000–37,600 | 336 / 336 |
| COP at 5°F / −15°C | 1.92–2.2 | 336 / 336 |
| Equipment / loop type | HP - Split System | 336 / 336 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 336 / 336 |
| Compressor staging | Continuously variable | 336 / 336 |
| Connected capability | No | 336 / 336 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EVM5X61M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218355664 | 19.00 | 9.00 | 36400 | 2.12 | EPA 4590774 → |
EVM5X61M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218355663 | 19.00 | 9.50 | 36800 | 2.10 | EPA 4590775 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1202422A*Cold climate designationAHRI reference: 218355662 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4590776 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218355661 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4590777 → |
EVM5X60M24A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218355660 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4590778 → |
EVM5X60M24A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218355658 | 19.00 | 9.00 | 36200 | 2.12 | EPA 4590780 → |
EVM5X60M24A*+WALLCON+ furnace: *96CTN0802120B*Cold climate designationAHRI reference: 218355657 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4590781 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN1002122A*Cold climate designationAHRI reference: 218355656 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4590782 → |
EVM5X60M21A*+WALLCON+ furnace: *97CTN0802120A*Cold climate designationAHRI reference: 218355655 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4590783 → |
EVM5X60M21A*+WALLCON+ furnace: *80CSU0802120B*Cold climate designationAHRI reference: 218355652 | 19.00 | 9.00 | 36400 | 2.12 | EPA 4590786 → |
EVD5X60M21A*+WALLCON+ furnace: *97CMN0802120B*Cold climate designationAHRI reference: 218355623 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4590787 → |
EVD5X60M21A*+WALLCON+ furnace: *95CSU1002122B*Cold climate designationAHRI reference: 218355617 | 19.00 | 9.00 | 36600 | 2.12 | EPA 4590793 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL1102120B*Cold climate designationAHRI reference: 218355611 | 19.00 | 9.50 | 36600 | 2.10 | EPA 4590799 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0902120B*Cold climate designationAHRI reference: 218355609 | 19.00 | 9.50 | 36600 | 2.12 | EPA 4590801 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0901716B*Cold climate designationAHRI reference: 218355607 | 19.00 | 9.00 | 36800 | 1.98 | EPA 4590803 → |
EVD5X60M21A*+WALLCON+ furnace: *80CTL0702120B*Cold climate designationAHRI reference: 218355605 | 19.00 | 9.00 | 36800 | 2.00 | EPA 4590805 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN1202422B*Cold climate designationAHRI reference: 218355599 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4590811 → |
EVD5X49M24A*+WALLCON+ furnace: *96CTN1002122B*Cold climate designationAHRI reference: 218355597 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4590813 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN1202422B*Cold climate designationAHRI reference: 218355596 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4590814 → |
EVD5X49M24A*+WALLCON+ furnace: *97CMN1002122B*Cold climate designationAHRI reference: 218355595 | 19.00 | 9.00 | 36600 | 2.00 | EPA 4590815 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →