SEER2 range16.1–19.3BTU/Wh
HSPF2 range9.5–10.8BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for ACIQ-18-HPD. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 7 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16.1–19.37 / 7
EER2 · BTU/Wh11.7–12.57 / 7
HSPF2 · BTU/Wh9.5–10.87 / 7
Cooling capacity · BTU/h18,0007 / 7
Heating capacity at 47°F / 8.3°C · BTU/h18,000–19,0007 / 7
Heating capacity at 17°F / −8.3°C · BTU/h14,700–15,3007 / 7
Heating capacity at 5°F / −15°C · BTU/h18,000–19,6007 / 7
COP at 5°F / −15°C1.8–2.127 / 7
Equipment / loop typeHP - Split System7 / 7
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)7 / 7
Compressor stagingContinuously variable7 / 7
Connected capabilityNo7 / 7

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ACIQ-18W-WMBCold climate designationAHRI reference: 21698078519.3010.80196002.10EPA 3998507
ACIQ-18-AHDCold climate designationAHRI reference: 21603224619.009.70180002.00EPA 3740673
ACIQ-18-PAHCold climate designationAHRI reference: 21603225319.0010.10186002.12EPA 3740680
ACIQ-18-M-PAHCold climate designationAHRI reference: 21845790019.0010.10186002.12EPA 4624540
ACIQ-18W-PBCold climate designationAHRI reference: 21698079316.8010.50190001.80EPA 4000031
ACIQ-24-ACL-BCold climate designationAHRI reference: 21698077016.109.50180002.06EPA 4000013
ACIQ-24-ACL-14-BCold climate designationAHRI reference: 21698076916.109.50180002.06EPA 4000016

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →