AC PRO / AIR-SOURCE HEAT PUMP

BH719M36P-**A

BH719M SERIES · BH719M Series · source records, page 5

144 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for BH719M36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20144 / 144
EER2 · BTU/Wh11–13.2144 / 144
HSPF2 · BTU/Wh7.8–8.5144 / 144
Cooling capacity · BTU/h21,600–35,800144 / 144
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000144 / 144
Heating capacity at 17°F / −8.3°C · BTU/h14,500–21,600144 / 144
Heating capacity at 5°F / −15°C · BTU/h13,600–17,000144 / 144
COP at 5°F / −15°C1.48–2.12144 / 144
Equipment / loop typeHP - Split System144 / 144
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)144 / 144
Compressor stagingContinuously variable144 / 144
Connected capabilityNo144 / 144

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC736[C,U]BT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21750409717.508.10151001.90EPA 4468506
BC736HCT-**+TDR+ furnace: B80UR802V4BXAHRI reference: 21750422717.508.00164002.08EPA 4468535
BC736HCT-**+TDR+ furnace: B92UR901E3CAHRI reference: 21750421217.508.20163002.06EPA 4468557
BC730HBT-**+TDR+ furnace: B80UR902E3BAHRI reference: 21750461617.508.20149001.88EPA 4468742
BC730HBT-**+TDR+ furnace: B92UR451E3BAHRI reference: 21750462917.508.50152001.88EPA 4468756
BC730HBT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21750463317.508.50151001.90EPA 4468762
BC730HBT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21750464517.508.20151001.90EPA 4468774
BC730HBT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21750464717.508.20152001.88EPA 4468776
BC730HBT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21750465117.508.20152001.88EPA 4468780
BC730HAT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21750467517.507.80149001.50EPA 4468798
BC730HAT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21750467817.507.80149001.50EPA 4468801
BC730HAT-**+TDR+ furnace: B80UR701E3AAHRI reference: 21750468317.507.80145001.48EPA 4468808
BC736HCT-**+TDR+ furnace: B97UR802V4CXAHRI reference: 21750424117.508.10165002.06EPA 4469405
BC730HBT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21754752317.508.20152001.90EPA 4469933
BC736[C,U]CT-**+TDR+ furnace: B80UR1002V5CXAHRI reference: 21845873917.508.20148001.94EPA 4617474
BC736[C,U]CT-**+TDR+ furnace: B95UR801E4CXAHRI reference: 21845871817.508.20149001.92EPA 4617480
BC736[C,U]CT-**+TDR+ furnace: B92UR1101E4CAHRI reference: 21845869417.508.20146001.96EPA 4617492
BC736[C,U]CT-**+TDR+ furnace: B97UR802V5CXAHRI reference: 21845868517.508.20150001.92EPA 4617495
BC736[C,U]CT-**+TDR+ furnace: B97UR902E4CAHRI reference: 21845867617.508.20148001.94EPA 4617501
BC736HCT-**+TDR+ furnace: B80UR1002V5CXAHRI reference: 21750423417.008.10164002.08EPA 4468469

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →