AC PRO / AIR-SOURCE HEAT PUMP

BH719M36P-**A

BH719M SERIES · BH719M Series · source records, page 2

144 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity21,600–35,800BTU/h

Each efficiency range summarizes published EPA records for BH719M36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20144 / 144
EER2 · BTU/Wh11–13.2144 / 144
HSPF2 · BTU/Wh7.8–8.5144 / 144
Cooling capacity · BTU/h21,600–35,800144 / 144
Heating capacity at 47°F / 8.3°C · BTU/h22,800–36,000144 / 144
Heating capacity at 17°F / −8.3°C · BTU/h14,500–21,600144 / 144
Heating capacity at 5°F / −15°C · BTU/h13,600–17,000144 / 144
COP at 5°F / −15°C1.48–2.12144 / 144
Equipment / loop typeHP - Split System144 / 144
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)144 / 144
Compressor stagingContinuously variable144 / 144
Connected capabilityNo144 / 144

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC724[C,U]BT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21750455319.008.50165002.04EPA 4468704
BC724[C,U]BT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21750456119.008.50164002.02EPA 4468708
BC724[C,U]BT-**+TDR+ furnace: B97UR402V3BXAHRI reference: 21750456719.008.50164002.02EPA 4468710
BC724[C,U]BT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21750456919.008.50164002.02EPA 4468711
BC724[C,U]BT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21750457119.008.50166002.02EPA 4468712
BC724[C,U]AT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21750458419.008.50166002.02EPA 4468719
BC724[C,U]AT-**+TDR+ furnace: B80UR451E3AAHRI reference: 21750458619.008.50162002.00EPA 4468720
BC724[C,U]AT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 21750459019.008.50164002.02EPA 4468722
BC730[C,U]BT-**+TDR+ furnace: B80UR902E3BAHRI reference: 21750459719.008.20136001.86EPA 4468725
BC730[C,U]BT-**+TDR+ furnace: B92UR451E3BAHRI reference: 21750460419.008.20141001.88EPA 4468733
BC730[C,U]BT-**+TDR+ furnace: B92UR701E3BAHRI reference: 21750460619.008.20140001.88EPA 4468735
BC730[C,U]BT-**+TDR+ furnace: B97UR452V3BAHRI reference: 21750461819.008.10138001.88EPA 4468746
BC730[C,U]BT-**+TDR+ furnace: B80UR602V3AXAHRI reference: 21750462319.008.10139001.86EPA 4468751
BC730[C,U]BT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 21750462719.008.10139001.86EPA 4468757
BC730[C,U]BT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21750463119.008.20141001.88EPA 4468760
BC730[C,U]AT-**+TDR+ furnace: B80UR401E3AXAHRI reference: 21750465519.008.20140001.88EPA 4468784
BC730[C,U]AT-**+TDR+ furnace: B80UR601E3AXAHRI reference: 21750465719.008.20140001.88EPA 4468786
BC730[C,U]AT-**+TDR+ furnace: B80UR702E3AAHRI reference: 21750466019.008.20141001.88EPA 4468788
BC730[C,U]AT-**+TDR+ furnace: B80UR451E3AAHRI reference: 21750466219.008.20137001.86EPA 4469476
BC724[C,U]AT-**+TDR+ furnace: B80UR702V3AAHRI reference: 21754749719.008.50164002.02EPA 4469854

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.