AC PRO / AIR-SOURCE HEAT PUMP

BH714S42P-**A

BH714S Series · source records, page 2

46 published source records · source checked Sep 21, 2026

SEER2 range15.2–15.5BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity41,000–42,000BTU/h

Each efficiency range summarizes published EPA records for BH714S42P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 46 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–15.546 / 46
EER2 · BTU/Wh12.6–13.246 / 46
HSPF2 · BTU/Wh7.8–846 / 46
Cooling capacity · BTU/h41,000–42,00046 / 46
Heating capacity at 47°F / 8.3°C · BTU/h39,000–40,00046 / 46
Heating capacity at 17°F / −8.3°C · BTU/h24,600–25,40046 / 46
Heating capacity at 5°F / −15°C · BTU/h19,300–20,80046 / 46
COP at 5°F / −15°C2–2.1246 / 46
Equipment / loop typeHP - Split System46 / 46
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)46 / 46
Compressor stagingSingle stage46 / 46
Connected capabilityNo46 / 46

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
BC749[C,U]CT-**+TDR+ furnace: B97UR1102V5CAHRI reference: 21649885915.507.80196002.04EPA 3847432 →
BC749CCT-**+TDR+ furnace: A98USMV090C16S*AHRI reference: 21696883615.507.80196002.04EPA 3996636 →
BC749CCT-**+TDR+ furnace: A98USMV110C20S*AHRI reference: 21696883815.507.80196002.04EPA 3996638 →
BC749[C,U]CT-**+TDR+ furnace: B97UR1002V5CXAHRI reference: 21637118115.207.80199002.06EPA 3813079 →
BC749[C,U]CT-**+TDR+ furnace: B95UR1001E5CXAHRI reference: 21637116615.207.80197002.04EPA 3813126 →
BC749[C,U]CT-**+TDR+ furnace: B97UR902E4CAHRI reference: 21637116815.207.80199002.06EPA 3813127 →
BC749[C,U]CT-**+TDR+ furnace: B92UR901E4CAHRI reference: 21637117315.207.80200002.06EPA 3813175 →
BC749[C,U]CT-**+TDR+ furnace: B96UR901E4CAHRI reference: 21637117615.207.80200002.06EPA 3813178 →
BAH7V48PT-**AHRI reference: 21637114715.208.00196002.08EPA 3813194 →
BC748[C,U]CT-**+TDR+ furnace: B92UR1101E5CAHRI reference: 21637115815.207.80206002.10EPA 3813200 →
BC748[C,U]CT-**+TDR+ furnace: B80UR1002V5CXAHRI reference: 21637116215.207.80206002.10EPA 3813203 →
BC748[C,U]CT-**+TDR+ furnace: B97UR802V4CXAHRI reference: 21637116315.207.80206002.10EPA 3813204 →
BC748[C,U]CT-**+TDR+ furnace: B97UR1002V5CXAHRI reference: 21637116415.207.80208002.10EPA 3813205 →
BC748[C,U]CT-**+TDR+ furnace: B97UR902E4CAHRI reference: 21637115115.207.80208002.10EPA 3813806 →
BC748[C,U]CT-**+TDR+ furnace: B97UR1102E5CAHRI reference: 21637115215.207.80206002.08EPA 3813807 →
BC748[C,U]CT-**+TDR+ furnace: B92UR901E3CAHRI reference: 21637115515.207.80204002.10EPA 3813809 →
BC748[C,U]CT-**+TDR+ furnace: B97UR1102V5CAHRI reference: 21649885815.207.80206002.10EPA 3847431 →
BC748[C,U]CT-**+TDR+ furnace: B80UR1102V5CAHRI reference: 21680160815.207.80206002.08EPA 3993087 →
BC748[C,U]CT-**+TDR+ furnace: B97UR902V3CAHRI reference: 21680160915.207.80206002.08EPA 3993088 →
BC749[C,U]CT-**+TDR+ furnace: B80UR1102V5CAHRI reference: 21680161115.207.80197002.04EPA 3993098 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →