BH714S18P-**A
BH714S Series
35 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for BH714S18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 35 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 35 / 35 |
| EER2 · BTU/Wh | 13–14.2 | 35 / 35 |
| HSPF2 · BTU/Wh | 7.8 | 35 / 35 |
| Cooling capacity · BTU/h | 18,000 | 35 / 35 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 17,500–18,000 | 35 / 35 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,500–11,200 | 35 / 35 |
| Heating capacity at 5°F / −15°C · BTU/h | 7,900–8,500 | 35 / 35 |
| COP at 5°F / −15°C | 1.86–2 | 35 / 35 |
| Equipment / loop type | HP - Split System | 35 / 35 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 35 / 35 |
| Compressor staging | Single stage | 35 / 35 |
| Connected capability | No | 35 / 35 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
BC730HAT-**+TDR+ furnace: B80UR702E3AAHRI reference: 216370781 | 16.50 | 7.80 | 8200 | 2.00 | EPA 3813081 → |
BC730HAT-**+TDR+ furnace: B80UR451E3AAHRI reference: 216370782 | 16.50 | 7.80 | 8100 | 1.98 | EPA 3813082 → |
BC730HAT-**+TDR+ furnace: B80UR701E3AAHRI reference: 216370783 | 16.50 | 7.80 | 8100 | 1.98 | EPA 3813083 → |
BC730HAT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 216370784 | 16.50 | 7.80 | 8100 | 1.98 | EPA 3813084 → |
BC730HAT-**+TDR+ furnace: B80UR702V3AAHRI reference: 216801561 | 16.50 | 7.80 | 8200 | 2.00 | EPA 3993080 → |
BC724HBT-**+TDR+ furnace: B97UR702E3BAHRI reference: 216370769 | 16.00 | 7.80 | 8200 | 1.94 | EPA 3813058 → |
BC724HBT-**+TDR+ furnace: B92UR701E3BAHRI reference: 216370772 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3813059 → |
BAH7V18PT-**AHRI reference: 216370717 | 16.00 | 7.80 | 8100 | 1.86 | EPA 3813060 → |
BAH7V24PT-**AHRI reference: 216370720 | 16.00 | 7.80 | 8400 | 1.98 | EPA 3813062 → |
BC724HAT-**+TDR+ furnace: B80UR702E3AAHRI reference: 216370761 | 16.00 | 7.80 | 8000 | 1.96 | EPA 3813064 → |
BC724HAT-**+TDR+ furnace: B80UR451E3AAHRI reference: 216370762 | 16.00 | 7.80 | 7900 | 1.94 | EPA 3813065 → |
BC724HAT-**+TDR+ furnace: B80UR701E3AAHRI reference: 216370763 | 16.00 | 7.80 | 8000 | 1.96 | EPA 3813066 → |
BC724HAT-**+TDR+ furnace: B80UR402V3AXAHRI reference: 216370764 | 16.00 | 7.80 | 8000 | 1.96 | EPA 3813067 → |
BC724HBT-**+TDR+ furnace: B95UR601E3BXAHRI reference: 216370766 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3813068 → |
BC724HBT-**+TDR+ furnace: B80UR902E3BAHRI reference: 216370767 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3813069 → |
BC724HBT-**+TDR+ furnace: B97UR452E3BAHRI reference: 216370768 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3813070 → |
BC724HBT-**+TDR+ furnace: B97UR602V3BXAHRI reference: 216370777 | 16.00 | 7.80 | 8300 | 1.96 | EPA 3813074 → |
BAH7E24PT-**AHRI reference: 216370719 | 16.00 | 7.80 | 8200 | 2.00 | EPA 3813740 → |
BC724HBT-**+TDR+ furnace: B80UR701E3BAHRI reference: 216370770 | 16.00 | 7.80 | 8200 | 1.94 | EPA 3813768 → |
BC724HBT-**+TDR+ furnace: B92UR451E3BAHRI reference: 216370771 | 16.00 | 7.80 | 8300 | 1.94 | EPA 3813769 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →