AC PRO / AIR-SOURCE HEAT PUMP

A7CP21V60P-**A

A7CP21V Series · source records, page 3

78 published source records · source checked Sep 21, 2026

SEER2 range16–20.5BTU/Wh
HSPF2 range8.1–9BTU/Wh
Cooling capacity52,000–56,000BTU/h

Each efficiency range summarizes published EPA records for A7CP21V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–20.578 / 78
EER2 · BTU/Wh11–1278 / 78
HSPF2 · BTU/Wh8.1–978 / 78
Cooling capacity · BTU/h52,000–56,00078 / 78
Heating capacity at 47°F / 8.3°C · BTU/h52,000–55,50078 / 78
Heating capacity at 17°F / −8.3°C · BTU/h40,000–46,00078 / 78
Heating capacity at 5°F / −15°C · BTU/h31,600–38,50078 / 78
COP at 5°F / −15°C2.06–2.1878 / 78
Equipment / loop typeHP - Split System78 / 78
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)78 / 78
Compressor stagingContinuously variable78 / 78
Connected capabilityNo78 / 78

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH60DX-**+TDR+ furnace: A97US2V080C20X*AHRI reference: 21746577019.508.50356002.06EPA 4431571 →
7EH51CX-**+TDR+ furnace: A80US2V080C20X*AHRI reference: 21749339219.508.50318002.06EPA 4433404 →
7EH51CX-**+TDR+ furnace: A80US2V090C20*AHRI reference: 21749339319.508.50316002.10EPA 4433405 →
7EH51CX-**+TDR+ furnace: A80US2V100C20X*AHRI reference: 21749339419.508.50318002.06EPA 4433406 →
7EH51CX-**+TDR+ furnace: A80US2V110C20*AHRI reference: 21749339519.508.50316002.08EPA 4433407 →
7EH51CX-**+TDR+ furnace: A80US2V110C20L*AHRI reference: 21749339619.508.50316002.08EPA 4433408 →
7EH51CX-**+TDR+ furnace: A98USMV110C20S*AHRI reference: 21749339819.508.50318002.08EPA 4433410 →
7EH51CX-**+TDR+ furnace: A97US2V090C20S*AHRI reference: 21749339919.508.50320002.06EPA 4433411 →
7EH51CX-**+TDR+ furnace: A97US2V110C20S*AHRI reference: 21772796619.508.50318002.06EPA 4512871 →
7E[C,U]49CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21797039319.508.20348002.10EPA 4566243 →
7E[C,U]60CX-**+TDR+ furnace: EFV16CCA*AHRI reference: 21797039419.508.20340002.16EPA 4566244 →
7E[C,U]49CX-**+TDR+ furnace: A80UH1E090C20*AHRI reference: 21746586119.008.50356002.10EPA 4431447 →
7E[C,U]49CX-**+TDR+ furnace: A96UH1E110C20S*AHRI reference: 21746586419.008.50358002.10EPA 4431450 →
7EH60DX-**+TDR+ furnace: A80UH1E090C20*AHRI reference: 21746586519.008.50358002.08EPA 4431451 →
7EH60DX-**+TDR+ furnace: A93UH1E110C20A*AHRI reference: 21746586819.008.50354002.08EPA 4431454 →
7EH60DX-**+TDR+ furnace: A80UH1E100C20X*AHRI reference: 21746587019.008.50358002.06EPA 4431456 →
7E[C,U]60CX-**+TDR+ furnace: A96UH1E110C20S*AHRI reference: 21746587719.008.50350002.14EPA 4431465 →
7E[C,U]60DX-**+TDR+ furnace: A80UH1E135D20*AHRI reference: 21746587919.008.50342002.14EPA 4431467 →
7AH1AV60PX-**Cold climate designationAHRI reference: 21746588119.008.50385002.16EPA 4431469 →
7EH51CX-**+TDR+ furnace: A97US2V080C20X*AHRI reference: 21749339719.008.50320002.06EPA 4433409 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →