AC PRO / AIR-SOURCE HEAT PUMP

A7CP21V60P-**A

A7CP21V Series

78 published source records · source checked Sep 21, 2026

SEER2 range16–20.5BTU/Wh
HSPF2 range8.1–9BTU/Wh
Cooling capacity52,000–56,000BTU/h

Each efficiency range summarizes published EPA records for A7CP21V60P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–20.578 / 78
EER2 · BTU/Wh11–1278 / 78
HSPF2 · BTU/Wh8.1–978 / 78
Cooling capacity · BTU/h52,000–56,00078 / 78
Heating capacity at 47°F / 8.3°C · BTU/h52,000–55,50078 / 78
Heating capacity at 17°F / −8.3°C · BTU/h40,000–46,00078 / 78
Heating capacity at 5°F / −15°C · BTU/h31,600–38,50078 / 78
COP at 5°F / −15°C2.06–2.1878 / 78
Equipment / loop typeHP - Split System78 / 78
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)78 / 78
Compressor stagingContinuously variable78 / 78
Connected capabilityNo78 / 78

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7E[C,U]60DX-**+TDR+ furnace: A80US2V135D20*AHRI reference: 21746578420.509.00342002.16EPA 4431417
7E[C,U]60DX-**+TDR+ furnace: A97US2V080C20X*AHRI reference: 21746578520.508.50346002.14EPA 4431418
7E[C,U]49CX-**+TDR+ furnace: A80US2V080C20X*AHRI reference: 21746575820.508.50356002.12EPA 4431423
7E[C,U]49CX-**+TDR+ furnace: A80US2V100C20X*AHRI reference: 21746576020.508.50356002.12EPA 4431425
7E[C,U]60CX-**+TDR+ furnace: A80US2V080C20X*AHRI reference: 21746577520.508.50348002.16EPA 4431441
7E[C,U]60CX-**+TDR+ furnace: A80US2V100C20X*AHRI reference: 21746577720.508.50348002.16EPA 4431442
7E[C,U]60CX-**+TDR+ furnace: A80US2V110C20*AHRI reference: 21746577820.508.50348002.16EPA 4431443
7E[C,U]60DX-**+TDR+ furnace: A98USMV135D20S*AHRI reference: 21746585820.508.50344002.14EPA 4431444
7E[C,U]60CX-**+TDR+ furnace: A80US2V090C20*AHRI reference: 21746577620.508.50346002.18EPA 4431574
7E[C,U]60CX-**+TDR+ furnace: A80US2V110C20L*AHRI reference: 21746577920.508.50348002.16EPA 4431575
7E[C,U]60DX-**+TDR+ furnace: A97US2V135D20S*AHRI reference: 21746578620.508.50344002.14EPA 4431576
7E[C,U]60CX-**+TDR+ furnace: A97US2V080C20X*AHRI reference: 21746578020.008.50352002.14EPA 4431413
7E[C,U]60CX-**+TDR+ furnace: A98USMV090C20S*AHRI reference: 21746578120.008.50350002.14EPA 4431414
7E[C,U]60CX-**+TDR+ furnace: A98USMV110C20S*AHRI reference: 21746578220.008.50350002.16EPA 4431415
7E[C,U]60CX-**+TDR+ furnace: A97US2V090C20S*AHRI reference: 21746578320.008.50352002.14EPA 4431416
7AH2AV60PXC**AHRI reference: 21746575420.009.00385002.14EPA 4431422
7E[C,U]49CX-**+TDR+ furnace: A80US2V090C20*AHRI reference: 21746575920.008.50354002.12EPA 4431424
7EH60DX-**+TDR+ furnace: A80US2V135D20*AHRI reference: 21746576120.008.50352002.10EPA 4431426
7E[C,U]49CX-**+TDR+ furnace: A80US2V110C20*AHRI reference: 21746576220.008.50356002.12EPA 4431427
7E[C,U]49CX-**+TDR+ furnace: A97US2V080C20X*AHRI reference: 21746576520.008.50358002.10EPA 4431429

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →