AC PRO / AIR-SOURCE HEAT PUMP

A7CP21V48P-**A

A7CP21V Series · source records, page 7

126 published source records · source checked Sep 21, 2026

SEER2 range15.7–20.5BTU/Wh
HSPF2 range7.8–9.6BTU/Wh
Cooling capacity45,000–48,000BTU/h

Each efficiency range summarizes published EPA records for A7CP21V48P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 126 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.7–20.5126 / 126
EER2 · BTU/Wh11–13.4126 / 126
HSPF2 · BTU/Wh7.8–9.6126 / 126
Cooling capacity · BTU/h45,000–48,000126 / 126
Heating capacity at 47°F / 8.3°C · BTU/h43,000–51,000126 / 126
Heating capacity at 17°F / −8.3°C · BTU/h35,000–44,000126 / 126
Heating capacity at 5°F / −15°C · BTU/h29,000–39,500126 / 126
COP at 5°F / −15°C1.92–2.2126 / 126
Equipment / loop typeHP - Split System126 / 126
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)126 / 126
Compressor stagingContinuously variable126 / 126
Connected capabilityNo126 / 126

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7ED48CX-**+TDRAHRI reference: 21746615417.008.10326002.04EPA 4469243
7E[C,U]60CX-**+TDRCold climate designationAHRI reference: 21746583616.509.00348002.10EPA 4469168
7E[C,U]50/60CX-**+TDRAHRI reference: 21746580216.208.20300002.10EPA 4469138
7EH60DX-**+TDRAHRI reference: 21746580316.008.50322001.92EPA 4469139
7EH51CX-**+TDRCold climate designationAHRI reference: 21746615316.008.20340002.02EPA 4469242
7E[C,U]60DX-**+TDRCold climate designationAHRI reference: 21746583715.708.20350001.98EPA 4469169

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →