AC PRO / AIR-SOURCE HEAT PUMP

A7CP21V36P-**A

A7CP21V Series · source records, page 6

149 published source records · source checked Sep 21, 2026

SEER2 range15.2–20BTU/Wh
HSPF2 range8.5–10.4BTU/Wh
Cooling capacity32,000–34,800BTU/h

Each efficiency range summarizes published EPA records for A7CP21V36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 149 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20149 / 149
EER2 · BTU/Wh11–12.2149 / 149
HSPF2 · BTU/Wh8.5–10.4149 / 149
Cooling capacity · BTU/h32,000–34,800149 / 149
Heating capacity at 47°F / 8.3°C · BTU/h30,400–34,800149 / 149
Heating capacity at 17°F / −8.3°C · BTU/h26,600–31,800149 / 149
Heating capacity at 5°F / −15°C · BTU/h18,400–25,400149 / 149
COP at 5°F / −15°C1.9–2.46149 / 149
Equipment / loop typeHP - Split System149 / 149
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)149 / 149
Compressor stagingContinuously variable149 / 149
Connected capabilityNo149 / 149

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30AX-**+TDR+ furnace: A80UH1E060A12X*Cold climate designationAHRI reference: 21746608917.508.50240001.94EPA 4469311
7ED30/36CX-**+TDR+ furnace: A93DF1E090C16A*AHRI reference: 21746609417.509.00191002.34EPA 4469315
7ED30/36CX-**+TDR+ furnace: A96DF1E090C16S*AHRI reference: 21746609517.509.00191002.36EPA 4469317
7EH30AX-**+TDR+ furnace: A80UH1E070A12*Cold climate designationAHRI reference: 21746609717.508.80240001.94EPA 4469319
7EH30BX-**+TDR+ furnace: A93UH1E030B12A*Cold climate designationAHRI reference: 21746610117.509.00226002.40EPA 4469323
7EH30BX-**+TDR+ furnace: A93UH1E045B12A*Cold climate designationAHRI reference: 21746610317.509.00224002.42EPA 4469325
7EH42CX-**+TDR+ furnace: A80US2V100C20X*Cold climate designationAHRI reference: 21746612617.509.60226001.94EPA 4469348
7EH42CX-**+TDR+ furnace: A80US2V110C20*Cold climate designationAHRI reference: 21746612717.509.60226001.94EPA 4469349
7EH42CX-**+TDR+ furnace: A80US2V110C20L*Cold climate designationAHRI reference: 21746612817.509.60226001.94EPA 4469350
7EH42CX-**+TDR+ furnace: A97US2V080C20X*Cold climate designationAHRI reference: 21746613017.509.60228001.92EPA 4469352
7EH42CX-**+TDR+ furnace: A98USMV090C20S*Cold climate designationAHRI reference: 21746613317.509.60226001.94EPA 4469355
7EH36CX-**+TDR+ furnace: A97US2V080C16X*AHRI reference: 21746614217.509.60216002.04EPA 4469364
7EH36CX-**+TDR+ furnace: A98USMV090C12S*AHRI reference: 21746614417.509.60216002.04EPA 4469366
7EH42CX-**+TDR+ furnace: A97US2V090C20S*Cold climate designationAHRI reference: 21746614517.509.60226001.94EPA 4469367
7EH36CX-**+TDR+ furnace: A97US2V090C12S*AHRI reference: 21746615017.509.60216002.04EPA 4469372
7EH30BX-**+TDR+ furnace: EFV12BCA*Cold climate designationAHRI reference: 21797038417.508.50226002.44EPA 4566236
7EH42CX-**+TDR+ furnace: EFV16CCA*Cold climate designationAHRI reference: 21797038517.509.00224001.92EPA 4566237
7E[C,U]36BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 21746590117.008.50216002.08EPA 4469193
7E[C,U]30BX-**+TDR+ furnace: A80UH2E090B16*AHRI reference: 21746605617.0010.40224002.28EPA 4469279
7E[C,U]30BX-**+TDR+ furnace: A80UH1E090B16*AHRI reference: 21746605817.0010.40224002.28EPA 4469281

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →