AC PRO / AIR-SOURCE HEAT PUMP

A7CP21V24P-**A

A7CP21V Series · source records, page 6

119 published source records · source checked Sep 21, 2026

SEER2 range15.2–20.5BTU/Wh
HSPF2 range7.8–10.2BTU/Wh
Cooling capacity21,600–24,000BTU/h

Each efficiency range summarizes published EPA records for A7CP21V24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 119 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–20.5119 / 119
EER2 · BTU/Wh11.2–13.4119 / 119
HSPF2 · BTU/Wh7.8–10.2119 / 119
Cooling capacity · BTU/h21,600–24,000119 / 119
Heating capacity at 47°F / 8.3°C · BTU/h24,000–27,400119 / 119
Heating capacity at 17°F / −8.3°C · BTU/h18,800–22,400119 / 119
Heating capacity at 5°F / −15°C · BTU/h13,900–18,600119 / 119
COP at 5°F / −15°C1.7–2.3119 / 119
Equipment / loop typeHP - Split System119 / 119
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)119 / 119
Compressor stagingContinuously variable119 / 119
Connected capabilityNo119 / 119

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7ED30/36BX-**+TDR+ furnace: A97DF2E070B16S*AHRI reference: 21746600318.008.50164002.02EPA 4431522
7EH30AX-**+TDR+ furnace: A80UH1E070A12*AHRI reference: 21746604218.009.00169002.04EPA 4431559
7ED30/36BX-**+TDR+ furnace: A80DF1E070B12*AHRI reference: 21746600418.008.50162002.04EPA 4431567
7ED30/36BX-**+TDR+ furnace: EFV08BCA*AHRI reference: 21797037518.008.20165001.98EPA 4566227
7E[C,U]24BX-**+TDR+ furnace: EFV08BCA*AHRI reference: 21797038018.007.80143001.70EPA 4566232
7ED30/36BX-**+TDR+ furnace: A96DF1E070B16S*AHRI reference: 21746600817.508.50164002.02EPA 4431525
7AH1AC30PX-**Cold climate designationAHRI reference: 21746589717.009.00181002.12EPA 4431491
7AH1AC24PX-**AHRI reference: 21746598017.009.80173002.06EPA 4431502
7E[C,U]30BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 21746588816.509.60178002.08EPA 4431482
7EH30BX-**+TDR+ furnace: A80UH2E090B16*Cold climate designationAHRI reference: 21746601516.509.00173002.04EPA 4431532
7ED30/36CX-**+TDRAHRI reference: 21746601916.508.20168001.98EPA 4431536
7E[C,U]30BX-**+TDRCold climate designationAHRI reference: 21746575316.009.40180002.04EPA 4431421
7E[C,U]30AX-**+TDRCold climate designationAHRI reference: 21746573916.009.40180002.04EPA 4431433
7ED30/36BX-**+TDRAHRI reference: 21746599716.008.20167001.98EPA 4431516
7EH30BX-**+TDRCold climate designationAHRI reference: 21746599816.008.50175001.98EPA 4431517
7EH24AX-**+TDRCold climate designationAHRI reference: 21746599916.008.20181001.94EPA 4431518
7EH30AX-**+TDRCold climate designationAHRI reference: 21746600015.508.50175002.00EPA 4431519
7E[C,U]24AX-**+TDRAHRI reference: 21746598715.208.20147001.70EPA 4431507
7E[C,U]24BX-**+TDRAHRI reference: 21746598915.208.20147001.70EPA 4431510

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →