AC PRO / AIR-SOURCE HEAT PUMP

4HP18V36P

4HP18V SERIES · source records, page 6

192 published source records · source checked Sep 21, 2026

SEER2 range16–19BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,000–34,800BTU/h

Each efficiency range summarizes published EPA records for 4HP18V36P. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 192 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–19192 / 192
EER2 · BTU/Wh11–12.3192 / 192
HSPF2 · BTU/Wh7.8–8.5192 / 192
Cooling capacity · BTU/h22,000–34,800192 / 192
Heating capacity at 47°F / 8.3°C · BTU/h22,000–34,800192 / 192
Heating capacity at 17°F / −8.3°C · BTU/h14,900–24,800192 / 192
Heating capacity at 5°F / −15°C · BTU/h14,100–20,000192 / 192
COP at 5°F / −15°C1.78–2.18192 / 192
Equipment / loop typeHP - Split System192 / 192
Refrigerant / source-reported GWPR-410A (GWP:2088)192 / 192
Compressor stagingContinuously variable192 / 192
Connected capabilityNo192 / 192

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH48BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21472907418.508.50185002.10EPA 4010650 →
E*1P23B+TDR+TXV+ furnace: 97G2UH070BE12AHRI reference: 21393415418.508.10146002.01EPA 4010718 →
EA(C,U)1P24B+TDR+TXV+ furnace: 97G2UH070BE12AHRI reference: 21393415718.507.80156002.03EPA 4010720 →
EAC4X24B+TDR+ furnace: 97G2UH070BE12AHRI reference: 21393416318.507.80156002.03EPA 4010724 →
EAH1P30B+TDR+TXV+ furnace: 97G2UH070BE12AHRI reference: 21393416818.508.50152002.11EPA 4010729 →
EAH1P36B+TDR+TXV+ furnace: 97G2UH070BE12AHRI reference: 21393644018.508.50167001.98EPA 4010832 →
E*1P23B+TDR+TXV+ furnace: 97G2UH030BE08AHRI reference: 21409188618.508.10143001.89EPA 4010852 →
EA(C,U)1P24B+TDR+TXV+ furnace: 97G2UH030BE08AHRI reference: 21409188718.508.10143001.88EPA 4010853 →
EAC4X24B+TDR+ furnace: 97G2UH030BE08AHRI reference: 21409188918.508.10143001.88EPA 4010855 →
EAC4X30B+ furnace: 95G1UH045BE12AHRI reference: 20690564418.008.10151001.97EPA 2447247 →
EAH1P30B+H4TXV01+ furnace: 92G1UH030BE12AHRI reference: 20690571118.008.10152001.99EPA 2447495 →
EAH1P30B+H4TXV01+ furnace: 96G1UH070BE12AHRI reference: 20690571918.008.50153002.03EPA 2447506 →
EAH1P30B+H4TXV01+ furnace: 96G2UH045BE12AHRI reference: 20932958818.008.50152002.02EPA 2447925 →
EAH1P30B+H4TXV01+ furnace: 96G2UH070BE12AHRI reference: 20932959018.008.50152002.02EPA 2447930 →
BCE7E24MAHRI reference: 20690546318.008.50152002.10EPA 2447947 →
E*1P23B+H4TXV01+ furnace: 96G1UH045BE12AHRI reference: 20690548218.008.10146001.90EPA 2447959 →
E*1P23B+H4TXV01+ furnace: 96G1UH070BE12AHRI reference: 20690548318.008.10146001.90EPA 2447960 →
E*1P23B+H4TXV01+ furnace: 96G1UH030BE08AHRI reference: 20690548118.008.10141001.88EPA 2447993 →
EA(C,U)1P24B+H4TXV01+ furnace: 96G1UH070BE12AHRI reference: 20690553418.007.80156001.94EPA 2448011 →
EA(C,U)1P24B+H4TXV01+ furnace: 96G1UH045BE12AHRI reference: 20690553318.007.80156001.93EPA 2448012 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →