AC PRO / AIR-SOURCE HEAT PUMP

4HP17L36P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 7

297 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.7BTU/Wh
Cooling capacity34,800–36,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L36P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 297 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8297 / 297
EER2 · BTU/Wh12.2–14297 / 297
HSPF2 · BTU/Wh7.8–8.7297 / 297
Cooling capacity · BTU/h34,800–36,000297 / 297
Heating capacity at 47°F / 8.3°C · BTU/h32,400–36,000297 / 297
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800297 / 297
Heating capacity at 5°F / −15°C · BTU/h16,800–19,200297 / 297
COP at 5°F / −15°C2.06–2.36297 / 297
Equipment / loop typeHP - Split System297 / 297
Refrigerant / source-reported GWPR-410A (GWP:2088)297 / 297
Compressor stagingSingle stage297 / 297
Connected capabilityNo297 / 297

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC50/60CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21470984816.207.80173002.12EPA 3495136
7EC50/60CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21470984916.207.80173002.12EPA 3495138
7EC50/60CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21470985116.207.80172002.14EPA 3495142
7EC50/60CX-0*+TDR+ furnace: 92G1UH110CE16AHRI reference: 21470985216.207.80170002.12EPA 3495143
7EC36BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21470981316.207.80172002.14EPA 3495169
7EH48BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21470971816.208.00174002.22EPA 3495195
7EH48BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470971916.208.00172002.20EPA 3495196
7EH48BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470972016.208.00172002.20EPA 3495198
7EH51CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21470974316.208.00176002.18EPA 3495220
7EH51CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21470974516.207.80173002.18EPA 3495222
7EH51CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21470974616.208.10176002.18EPA 3495223
7ED48CX-0*+TDR+ furnace: 96G1DF090CE16AHRI reference: 21470978016.208.70191002.34EPA 3495242
7ED48CX-0*+TDR+ furnace: 96G1DF110CE20AHRI reference: 21470978116.208.70189002.34EPA 3495244
7EC50/60CX-0*+TDR+ furnace: 96G1UH090CE16AHRI reference: 21470985416.207.80172002.12EPA 3495265
7AH1AV42PX-0*AHRI reference: 21486550216.208.10174002.22EPA 3553834
EAC4X50/60C+TDR+ furnace: 92G1UH110CE20AHRI reference: 21032780416.007.80172002.12EPA 2455778
BCE7E36M*4XAHRI reference: 21032769016.008.50185002.28EPA 2455811
EAC4X36A+TDR+ furnace: 80G2UH070AE12AHRI reference: 21032777116.007.80170002.12EPA 2455812
EAC4X36A+TDR+ furnace: 80G2UH070AE12LAHRI reference: 21032777216.007.80170002.12EPA 2455871
EA(C;U)1P50/60C+TDR+TXV+ furnace: 95G1UH100CE20XAHRI reference: 21032772216.007.80172002.12EPA 2456019

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.