AC PRO / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 12

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21032795215.407.80144002.20EPA 2457026
EAC4X30B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21032794315.407.80143002.18EPA 2457031
EAC4X30B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032794415.407.80143002.18EPA 2457644
EA(C;U)1P30B+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21032785315.407.80143002.18EPA 2457793
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032785115.407.80143002.18EPA 2459000
BCE5V30M*4XAHRI reference: 21032783315.408.10139002.16EPA 2459017
EAH1P36C*+TDR+TXV+ furnace: 95G1UH080CE16XAHRI reference: 21173592815.408.30145002.22EPA 2466642
EAH1P36C*+TDR+TXV+ furnace: 95G1UH100CE20XAHRI reference: 21173593815.408.50148002.24EPA 2467533
EAD4X-42B+TDR+ furnace: 96G1DF045BE12AHRI reference: 21326521115.408.60154002.30EPA 2839794
7EH36CX-0*+TDR+ furnace: 80G1UH100CE20XAHRI reference: 21470957615.408.30149002.22EPA 3494704
7EH36CX-0*+TDR+ furnace: 95G1UH080CE16XAHRI reference: 21470957715.408.30145002.22EPA 3494759
7EH36CX-0*+TDR+ furnace: 95G1UH100CE20XAHRI reference: 21470957815.408.50148002.24EPA 3494780
7EC30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21470963515.407.80144002.20EPA 3495067
7EC30BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21470963615.407.80143002.18EPA 3495068
7EC30BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21470963715.407.80143002.18EPA 3495072
7EC30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21470961915.407.80143002.18EPA 3495130
7EC30BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21470962515.408.00145002.16EPA 3495155
7EC30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470962615.407.80144002.14EPA 3495156
7ED42BX-0*+TDR+ furnace: 96G1DF045BE12AHRI reference: 21470960615.408.60154002.30EPA 3495293
7AH1AV30PX-0*AHRI reference: 21486546715.408.10139002.16EPA 3553771