AC PRO / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 10

249 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,600BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 249 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2249 / 249
EER2 · BTU/Wh12.2–13.5249 / 249
HSPF2 · BTU/Wh7.8–8.6249 / 249
Cooling capacity · BTU/h28,200–30,600249 / 249
Heating capacity at 47°F / 8.3°C · BTU/h26,600–30,000249 / 249
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600249 / 249
Heating capacity at 5°F / −15°C · BTU/h13,200–15,400249 / 249
COP at 5°F / −15°C1.96–2.36249 / 249
Equipment / loop typeHP - Split System249 / 249
Refrigerant / source-reported GWPR-410A (GWP:2088)249 / 249
Compressor stagingSingle stage249 / 249
Connected capabilityNo249 / 249

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7ED42BX-0*+TDR+ furnace: 97G2DF045BE12AHRI reference: 21470959915.608.50151002.32EPA 3494835
7ED42BX-0*+TDR+ furnace: 97G2DF070BE16AHRI reference: 21470960015.608.50151002.32EPA 3494838
7EH30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21470955315.607.80139001.98EPA 3494903
7EH30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21470955615.607.80138002.08EPA 3494913
7EC36BX-0*+TDR+ furnace: 96G1UH045BE12AHRI reference: 21470966915.608.10146002.26EPA 3494941
7EC36BX-0*+TDR+ furnace: 96G1UH070BE12AHRI reference: 21470967015.608.10143002.26EPA 3494973
7EC36BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21470965815.608.10145002.26EPA 3494985
7EC30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21470963815.608.10145002.18EPA 3495041
7EH36CX-0*+TDR+ furnace: 92G1UH090CE12AHRI reference: 21470959015.608.30147002.24EPA 3495050
7EC30BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21470963215.608.00143002.20EPA 3495063
7EC30BX-0*+TDR+ furnace: 92G1UH045BE12AHRI reference: 21470963315.608.00144002.20EPA 3495064
7EC30BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21470963415.608.00144002.20EPA 3495065
7EH36CX-0*+TDR+ furnace: 92G1UH090CE16AHRI reference: 21470959115.608.30146002.24EPA 3495071
7EH36CX-0*+TDR+ furnace: 97G2UH090CV12AHRI reference: 21470958315.608.30147002.22EPA 3495074
7EH36CX-0*+TDR+ furnace: 97G2UH110CE20AHRI reference: 21470958515.608.50148002.24EPA 3495076
7EH36CX-0*+TDR+ furnace: 80G1UH110CE20AHRI reference: 21470958815.608.30146002.22EPA 3495107
7EH36CX-0*+TDR+ furnace: 80G1UH110CE20LAHRI reference: 21470958915.608.30146002.22EPA 3495108
7EH30BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21470956215.607.80137002.06EPA 3495114
7EH30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470956315.607.80136002.06EPA 3495115
7EC30AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21470961615.608.00144002.20EPA 3495126

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →