AC PRO / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 4

257 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 257 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17257 / 257
EER2 · BTU/Wh12.5–14257 / 257
HSPF2 · BTU/Wh7.8–8.2257 / 257
Cooling capacity · BTU/h22,400–24,000257 / 257
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600257 / 257
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700257 / 257
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500257 / 257
COP at 5°F / −15°C2–2.18257 / 257
Equipment / loop typeHP - Split System257 / 257
Refrigerant / source-reported GWPR-410A (GWP:2088)257 / 257
Compressor stagingSingle stage257 / 257
Connected capabilityNo257 / 257

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EH30BX-0*+TDR+ furnace: 96G1UH030BE08AHRI reference: 21470945816.407.80102002.02EPA 3494925
7EH30BX-0*+TDR+ furnace: 80G2UH090BV16AHRI reference: 21470946116.407.80104002.04EPA 3494930
7EH30AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21470943516.408.00102002.08EPA 3494950
7EH30AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21470943716.408.00104002.14EPA 3494952
7EH30AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21470943616.408.00102002.08EPA 3494953
7EC30BX-0*+TDR+ furnace: 80G2UH090BE16AHRI reference: 21470952716.408.00104002.06EPA 3494955
7EC30BX-0*+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21470952816.408.00104002.06EPA 3494956
7EC24BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470949916.407.80104002.04EPA 3494959
7EC30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470953216.407.80104002.06EPA 3494963
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470953316.407.80104002.06EPA 3494964
7EC24BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470950016.407.80104002.04EPA 3494991
7EH30AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21470943816.408.00104002.14EPA 3494993
7EC24BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470950116.407.80104002.04EPA 3494994
7EH30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21470943916.408.10106002.12EPA 3494995
7EH30BX-0*+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21470944116.407.80106002.02EPA 3494996
7ED30/36CX-0*+TDR+ furnace: 96G1DF090CE16AHRI reference: 21470947616.408.20112002.10EPA 3495078
7EC30AX-0*+TDR+ furnace: 80G2UH045AE12AHRI reference: 21470951416.407.80102002.06EPA 3495120
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470953416.407.80104002.06EPA 3495172
7EC30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21470952116.407.80104002.04EPA 3495258
7EC24BX-0*+TDR+ furnace: 80G1UH090BE16AHRI reference: 21470950216.407.80104002.08EPA 3495274

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →