AC PRO / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 5

256 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8256 / 256
EER2 · BTU/Wh12.2–14256 / 256
HSPF2 · BTU/Wh7.8–8.5256 / 256
Cooling capacity · BTU/h18,000256 / 256
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000256 / 256
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100256 / 256
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700256 / 256
COP at 5°F / −15°C1.9–2.16256 / 256
Equipment / loop typeHP - Split System256 / 256
Refrigerant / source-reported GWPR-410A (GWP:2088)256 / 256
Compressor stagingSingle stage256 / 256
Connected capabilityNo256 / 256

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 21173433316.408.1082002.06EPA 2466173
EAH1P24B*+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21173457316.408.1082002.10EPA 2466597
EAH1P24B*+TDR+TXV+ furnace: 80G2UH090BE12AHRI reference: 21173443716.408.1082002.08EPA 2466605
EAH1P30B*+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21173476416.407.8078001.98EPA 2467025
EAH1P30B*+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21173481416.407.8077001.98EPA 2467044
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AE12AHRI reference: 21173432016.408.1082002.06EPA 2467051
EAH1P30B*+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21173486216.408.0080002.00EPA 2467489
EAD4X-30/36B+TDR+ furnace: 96G1DF045BE12AHRI reference: 21326518516.408.3087002.10EPA 2839642
7EH24AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21470929016.408.1082002.06EPA 3491862
7EH30BX-0*+TDR+ furnace: 92G1UH030BE12AHRI reference: 21470933316.407.8078001.98EPA 3494570
7EH30BX-0*+TDR+ furnace: 97G2UH070BE12AHRI reference: 21470932716.407.8077002.00EPA 3494634
7EC24AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21470936116.408.0082002.10EPA 3494657
7EC24AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21470936216.408.0082002.10EPA 3494661
7EC24BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21470936716.408.1081002.12EPA 3494674
7EC30AX-0*+TDR+ furnace: 80G1UH070AE12AHRI reference: 21470939316.407.8077001.98EPA 3494680
7EC30AX-0*+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21470939416.407.8077001.98EPA 3494681
7EC30BX-0*+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21470939816.407.8077001.98EPA 3494685
7EC30BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21470939916.407.8077002.00EPA 3494687
7EC24BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470937316.408.1084002.08EPA 3494694
7EC24BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470937416.408.0082002.10EPA 3494696

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →