AC PRO / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17L · 4HP17L SERIES · 4HP17L Series · source records, page 2

256 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 256 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8256 / 256
EER2 · BTU/Wh12.2–14256 / 256
HSPF2 · BTU/Wh7.8–8.5256 / 256
Cooling capacity · BTU/h18,000256 / 256
Heating capacity at 47°F / 8.3°C · BTU/h16,000–18,000256 / 256
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100256 / 256
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700256 / 256
COP at 5°F / −15°C1.9–2.16256 / 256
Equipment / loop typeHP - Split System256 / 256
Refrigerant / source-reported GWPR-410A (GWP:2088)256 / 256
Compressor stagingSingle stage256 / 256
Connected capabilityNo256 / 256

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
7EC30AX-0*+TDR+ furnace: 80G2UH070AE12AHRI reference: 21470938916.808.0076001.98EPA 3494631
7EC30AX-0*+TDR+ furnace: 80G1UH045AE12AHRI reference: 21470939116.807.8077002.00EPA 3494635
7EH30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470932816.808.0078002.00EPA 3494636
7EC30AX-0*+TDR+ furnace: 80G1UH045AE12LAHRI reference: 21470939216.807.8077002.00EPA 3494656
7EC30BX-0*+TDR+ furnace: 80G2UH090BE12AHRI reference: 21470940016.808.0076002.00EPA 3494688
7EC30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21470940616.808.0078002.00EPA 3494836
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12AHRI reference: 21470940716.807.8077001.98EPA 3494837
7EC30BX-0*+TDR+ furnace: 80G1UH070BE12LAHRI reference: 21470940816.807.8077001.98EPA 3494839
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032818316.608.0080001.98EPA 2455786
EAC4X30B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21032830416.607.8077002.02EPA 2455917
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21032819116.607.8077002.02EPA 2457419
EAC4X30A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032829616.608.0080001.98EPA 2458817
EAH1P30B*+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21173466716.607.8076002.00EPA 2463222
EAD4X-30/36B+TDR+ furnace: 92G1DF070BE12AHRI reference: 21326518416.608.5089002.10EPA 2839643
EAD4X-30/36B+TDR+ furnace: 92G1DF045BE12AHRI reference: 21326518316.608.4089002.10EPA 2839733
7EH30BX-0*+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21470932116.607.8076002.00EPA 3494627
7EH30BX-0*+TDR+ furnace: 97G2UH045BE12AHRI reference: 21470932516.607.8077002.02EPA 3494632
7EH30BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21470932616.608.0078002.00EPA 3494633
7EC30AX-0*+TDR+ furnace: 80G2UH070AV12AHRI reference: 21470939516.608.0080001.98EPA 3494683
7EC30BX-0*+TDR+ furnace: 92G1UH070BE12AHRI reference: 21470941316.607.8077002.02EPA 3494769

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →