AIREVANTAGE / AIR-SOURCE HEAT PUMP
A5H7V24AKAA
A5H Series · EPA record 4695890
Source checked Sep 21, 2026
Performance & equipment details
Values below belong to EPA record 4695890. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 16.40 |
| EER2 · BTU/Wh | 8.00 |
| HSPF2 · BTU/Wh | 8.70 |
| Cooling capacity · BTU/h | 23000 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23000 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17100 |
| Heating capacity at 5°F / −15°C · BTU/h | 16300 |
| COP at 5°F / −15°C | 1.78 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) |
| Compressor staging | Continuously variable |
| Connected capability | No |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+A5H7V24AKAAIndoor unit
ACVE245CBAHRI reference 218729467 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for A5H7V24AKAA →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 4695890 | EPA Sep 21, 2026 |
| markets | United States, Canada | EPA Sep 21, 2026 |
| cop at 5 f | 1.78 | EPA Sep 21, 2026 |
| eer2 btu wh | 8.00 | EPA Sep 21, 2026 |
| series name | A5H Series | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 8.70 | EPA Sep 21, 2026 |
| model number | A5H7V24AKAA | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 16.40 | EPA Sep 21, 2026 |
| date certified | 2026-09-01T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Continuously variable | EPA Sep 21, 2026 |
| energy star partner | Boreal International, Corp. | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| refrigerant with gwp | R-454B (GWP:470 | Lower GWP) | EPA Sep 21, 2026 |
| ahri reference number | 218729467 | EPA Sep 21, 2026 |
| cooling capacity btu h | 23000 | EPA Sep 21, 2026 |
| outdoor unit brand name | AIREVANTAGE | EPA Sep 21, 2026 |
| date available on market | 2026-08-15T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | ACVE245CB | EPA Sep 21, 2026 |
| energy star model identifier | ES_1145910_A5H7V24AKAA_08252026220000_28218729467 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 16300 | EPA Sep 21, 2026 |
| meets most efficient criteria | No | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 17100 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 23000 | EPA Sep 21, 2026 |
| meets peak cooling requirements | No | EPA Sep 21, 2026 |
| controls verification procedure cvp test | ENERGY STAR CVP Test | EPA Sep 21, 2026 |