VillaTherm / AIR-SOURCE HEAT PUMP
VHP-UCHA-36HDCT-A
SPLIT AHU · EPA record 4683489
Source checked Sep 21, 2026
Performance & equipment details
Values below belong to EPA record 4683489. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 18.00 |
| EER2 · BTU/Wh | 11.00 |
| HSPF2 · BTU/Wh | 10.00 |
| Cooling capacity · BTU/h | 34200 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34200 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31400 |
| Heating capacity at 5°F / −15°C · BTU/h | 25600 |
| COP at 5°F / −15°C | 2.30 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) |
| Compressor staging | Continuously variable |
| Connected capability | No |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+VHP-UCHA-36HDCT-AIndoor unit
VAH-UCHA-36SHDCALN2AHRI reference 218696918 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for VHP-UCHA-36HDCT-A →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 4683489 | EPA Sep 21, 2026 |
| markets | United States | EPA Sep 21, 2026 |
| cop at 5 f | 2.30 | EPA Sep 21, 2026 |
| eer2 btu wh | 11.00 | EPA Sep 21, 2026 |
| series name | SPLIT AHU | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 10.00 | EPA Sep 21, 2026 |
| model number | VHP-UCHA-36HDCT-A | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 18.00 | EPA Sep 21, 2026 |
| date certified | 2026-08-20T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Continuously variable | EPA Sep 21, 2026 |
| energy star partner | Villara Corporation | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| refrigerant with gwp | R-32 (GWP:675 | Lower GWP) | EPA Sep 21, 2026 |
| ahri reference number | 218696918 | EPA Sep 21, 2026 |
| cooling capacity btu h | 34200 | EPA Sep 21, 2026 |
| outdoor unit brand name | VillaTherm | EPA Sep 21, 2026 |
| date available on market | 2026-08-06T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | VAH-UCHA-36SHDCALN2 | EPA Sep 21, 2026 |
| energy star model identifier | ES_1147141_VHP-UCHA-36HDCT-A_08052026000002_28218696918 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 25600 | EPA Sep 21, 2026 |
| meets most efficient criteria | Yes | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 31400 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 34200 | EPA Sep 21, 2026 |
| meets peak cooling requirements | Yes | EPA Sep 21, 2026 |
| controls verification procedure cvp test | DOE Federal CVP Test,ENERGY STAR CVP Test | EPA Sep 21, 2026 |