Bestcold / AIR-SOURCE HEAT PUMP

MYORU48NA22BCH18ES

Gable Series · EPA record 4679105

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4679105. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh18.00
EER2 · BTU/Wh11.20
HSPF2 · BTU/Wh8.80
Cooling capacity · BTU/h48000
Heating capacity at 47°F / 8.3°C · BTU/h48000
Heating capacity at 17°F / −8.3°C · BTU/h29800
Heating capacity at 5°F / −15°C · BTU/h35200
COP at 5°F / −15°C2.10
Equipment / loop typeHP - Single Package
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitMYORU48NA22BCH18ES
+
Indoor unitIntegrated single package

AHRI reference 218690032 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for MYORU48NA22BCH18ES

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4679105EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.10EPA Sep 21, 2026
eer2 btu wh11.20EPA Sep 21, 2026
series nameGable SeriesEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh8.80EPA Sep 21, 2026
model numberMYORU48NA22BCH18ESEPA Sep 21, 2026
product typeHP - Single PackageEPA Sep 21, 2026
seer2 btu wh18.00EPA Sep 21, 2026
date certified2026-08-20T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerMoyu Technology Co., Ltd ZhuhaiEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
refrigerant with gwpR-32 (GWP:675 | Lower GWP)EPA Sep 21, 2026
ahri reference number218690032EPA Sep 21, 2026
cooling capacity btu h48000EPA Sep 21, 2026
outdoor unit brand nameBestcoldEPA Sep 21, 2026
date available on market2026-07-21T00:00:00.000EPA Sep 21, 2026
energy star model identifierES_1153047_MYORU48NA22BCH18ES_07212026050002_28218690032EPA Sep 21, 2026
heating capacity at 5 f btu h35200EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h29800EPA Sep 21, 2026
heating capacity at 47 f btu h48000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testDOE Federal CVP TestEPA Sep 21, 2026