Kenmore / AIR-SOURCE HEAT PUMP

XH618E2S11

LX SERIES · EPA record 4652169

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4652169. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh15.20
EER2 · BTU/Wh12.50
HSPF2 · BTU/Wh7.80
Cooling capacity · BTU/h17000
Heating capacity at 47°F / 8.3°C · BTU/h16400
Heating capacity at 17°F / −8.3°C · BTU/h10900
Heating capacity at 5°F / −15°C · BTU/h8800
COP at 5°F / −15°C2.30
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingSingle stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitXH618E2S11
+
Indoor unitCTM30B5ACS2
+
Required furnaceZ8ES080B12SMPS1*

AHRI reference 218601813 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for XH618E2S11

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4652169EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.30EPA Sep 21, 2026
eer2 btu wh12.50EPA Sep 21, 2026
series nameLX SERIESEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh7.80EPA Sep 21, 2026
model numberXH618E2S11EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh15.20EPA Sep 21, 2026
date certified2026-07-07T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingSingle stageEPA Sep 21, 2026
energy star partnerJohnson Controls, Inc.EPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model numberZ8ES080B12SMPS1*EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number218601813EPA Sep 21, 2026
cooling capacity btu h17000EPA Sep 21, 2026
outdoor unit brand nameKenmoreEPA Sep 21, 2026
date available on market2026-06-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCTM30B5ACS2EPA Sep 21, 2026
energy star model identifierES_21045_XH618E2S11_06102026180117_28218601813EPA Sep 21, 2026
heating capacity at 5 f btu h8800EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h10900EPA Sep 21, 2026
heating capacity at 47 f btu h16400EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026