Trane / AIR-SOURCE HEAT PUMP

N5HP5048A1

Advantage 15 Heat Pump · EPA record 4621643

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4621643. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh12.00
HSPF2 · BTU/Wh8.10
Cooling capacity · BTU/h45500
Heating capacity at 47°F / 8.3°C · BTU/h42000
Heating capacity at 17°F / −8.3°C · BTU/h28800
Heating capacity at 5°F / −15°C · BTU/h22200
COP at 5°F / −15°C2.21
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingSingle stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitN5HP5048A1
+
Indoor unit5TXCD010AS3+TSTAT
+
Required furnaceA951X120DU5SA

AHRI reference 218469861 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for N5HP5048A1

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4621643EPA Sep 21, 2026
marketsUnited StatesEPA Sep 21, 2026
cop at 5 f2.21EPA Sep 21, 2026
eer2 btu wh12.00EPA Sep 21, 2026
series nameAdvantage 15 Heat PumpEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh8.10EPA Sep 21, 2026
model numberN5HP5048A1EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
date certified2026-06-29T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingSingle stageEPA Sep 21, 2026
energy star partnerTrane and American Standard Heating and Air ConditioningEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model numberA951X120DU5SAEPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number218469861EPA Sep 21, 2026
cooling capacity btu h45500EPA Sep 21, 2026
outdoor unit brand nameTraneEPA Sep 21, 2026
date available on market2026-05-26T00:00:00.000EPA Sep 21, 2026
indoor unit model number5TXCD010AS3+TSTATEPA Sep 21, 2026
energy star model identifierES_1075581_N5HP5048A1_05272026160012_28218469861EPA Sep 21, 2026
heating capacity at 5 f btu h22200EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h28800EPA Sep 21, 2026
heating capacity at 47 f btu h42000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026