SINCLAIR AIR CONDITIONING / AIR-SOURCE HEAT PUMP

BH719M36P-**A

BH719M SERIES · EPA record 4617473

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4617473. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh17.50
EER2 · BTU/Wh11.20
HSPF2 · BTU/Wh8.20
Cooling capacity · BTU/h35200
Heating capacity at 47°F / 8.3°C · BTU/h32200
Heating capacity at 17°F / −8.3°C · BTU/h18700
Heating capacity at 5°F / −15°C · BTU/h14800
COP at 5°F / −15°C1.94
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitBH719M36P-**A
+
Indoor unitBC736[C,U]CT-**+TDR
+
Required furnaceB80UR1002V5CX

AHRI reference 218458740 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for BH719M36P-**A

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4617473EPA Sep 21, 2026
marketsUnited StatesEPA Sep 21, 2026
cop at 5 f1.94EPA Sep 21, 2026
eer2 btu wh11.20EPA Sep 21, 2026
series nameBH719M SERIESEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh8.20EPA Sep 21, 2026
model numberBH719M36P-**AEPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh17.50EPA Sep 21, 2026
date certified2026-06-09T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerLennox IndustriesEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model numberB80UR1002V5CXEPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number218458740EPA Sep 21, 2026
cooling capacity btu h35200EPA Sep 21, 2026
outdoor unit brand nameSINCLAIR AIR CONDITIONINGEPA Sep 21, 2026
date available on market2026-05-12T00:00:00.000EPA Sep 21, 2026
indoor unit model numberBC736[C,U]CT-**+TDREPA Sep 21, 2026
installation capabilitiesAutomatic system discovery,Preprogrammed system tests,Test mode for manual measurementsEPA Sep 21, 2026
energy star model identifierES_1082495_BH719M36P-**A_05142026100003_28218458740EPA Sep 21, 2026
heating capacity at 5 f btu h14800EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h18700EPA Sep 21, 2026
heating capacity at 47 f btu h32200EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testDOE Federal CVP TestEPA Sep 21, 2026