GE / AIR-SOURCE HEAT PUMP

NS16H30SA5-**A

NS16H Series · EPA record 4577827

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4577827. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh15.50
EER2 · BTU/Wh12.80
HSPF2 · BTU/Wh7.80
Cooling capacity · BTU/h29000
Heating capacity at 47°F / 8.3°C · BTU/h26600
Heating capacity at 17°F / −8.3°C · BTU/h17100
Heating capacity at 5°F / −15°C · BTU/h13400
COP at 5°F / −15°C1.94
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingSingle stage
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitNS16H30SA5-**A
+
Indoor unitNCHC30BT5*-**+TDR
+
Required furnaceNF97U045T3B*

AHRI reference 218159782 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for NS16H30SA5-**A

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4577827EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.94EPA Sep 21, 2026
eer2 btu wh12.80EPA Sep 21, 2026
series nameNS16H SeriesEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh7.80EPA Sep 21, 2026
model numberNS16H30SA5-**AEPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh15.50EPA Sep 21, 2026
date certified2026-04-22T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingSingle stageEPA Sep 21, 2026
energy star partnerGE Appliances, a Haier CompanyEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model numberNF97U045T3B*EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number218159782EPA Sep 21, 2026
cooling capacity btu h29000EPA Sep 21, 2026
outdoor unit brand nameGEEPA Sep 21, 2026
date available on market2025-11-06T00:00:00.000EPA Sep 21, 2026
indoor unit model numberNCHC30BT5*-**+TDREPA Sep 21, 2026
energy star model identifierES_1123206_NS16H30SA5-**A_03052026093000_28218159782EPA Sep 21, 2026
heating capacity at 5 f btu h13400EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h17100EPA Sep 21, 2026
heating capacity at 47 f btu h26600EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testNoneEPA Sep 21, 2026