ACIQ / AIR-SOURCE HEAT PUMP

N5H9V36*K*AAA*

Performance 19 SEER2 VS HP · EPA record 4567422

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4567422. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.00
EER2 · BTU/Wh12.00
HSPF2 · BTU/Wh9.00
Cooling capacity · BTU/h36600
Heating capacity at 47°F / 8.3°C · BTU/h36400
Heating capacity at 17°F / −8.3°C · BTU/h36600
Heating capacity at 5°F / −15°C · BTU/h26200
COP at 5°F / −15°C2.14
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitN5H9V36*K*AAA*
+
Indoor unitEVD5X48M21A*
+
Required furnace*80CTL1102120B*

AHRI reference 218017635 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for N5H9V36*K*AAA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4567422EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.14EPA Sep 21, 2026
eer2 btu wh12.00EPA Sep 21, 2026
series namePerformance 19 SEER2 VS HPEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.00EPA Sep 21, 2026
model numberN5H9V36*K*AAA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.00EPA Sep 21, 2026
date certified2026-09-16T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number*80CTL1102120B*EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number218017635EPA Sep 21, 2026
cooling capacity btu h36600EPA Sep 21, 2026
outdoor unit brand nameACIQEPA Sep 21, 2026
date available on market2025-01-14T00:00:00.000EPA Sep 21, 2026
indoor unit model numberEVD5X48M21A*EPA Sep 21, 2026
energy star model identifierES_1020846_N5H9V36*K*AAA*_12042025133454_28218017635EPA Sep 21, 2026
heating capacity at 5 f btu h26200EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h36600EPA Sep 21, 2026
heating capacity at 47 f btu h36400EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testDOE Federal CVP TestEPA Sep 21, 2026