BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

249VAN048**AA*

Preferred 19 SEER2 VS HP · EPA record 4542382

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4542382. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh16.50
EER2 · BTU/Wh11.00
HSPF2 · BTU/Wh9.00
Cooling capacity · BTU/h45000
Heating capacity at 47°F / 8.3°C · BTU/h49500
Heating capacity at 17°F / −8.3°C · BTU/h40500
Heating capacity at 5°F / −15°C · BTU/h36800
COP at 5°F / −15°C2.10
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unit249VAN048**AA*
+
Indoor unitCAA**4821AM*
+
Required furnace83*CB36040C17***

AHRI reference 217928559 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for 249VAN048**AA*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4542382EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f2.10EPA Sep 21, 2026
eer2 btu wh11.00EPA Sep 21, 2026
series namePreferred 19 SEER2 VS HPEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.00EPA Sep 21, 2026
model number249VAN048**AA*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh16.50EPA Sep 21, 2026
date certified2026-09-16T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number83*CB36040C17***EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number217928559EPA Sep 21, 2026
cooling capacity btu h45000EPA Sep 21, 2026
outdoor unit brand nameBRYANT HEATING AND COOLING SYSTEMSEPA Sep 21, 2026
date available on market2025-10-15T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCAA**4821AM*EPA Sep 21, 2026
energy star model identifierES_1020846_249VAN048**AA*_11042025015319_28217928559EPA Sep 21, 2026
heating capacity at 5 f btu h36800EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h40500EPA Sep 21, 2026
heating capacity at 47 f btu h49500EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testDOE Federal CVP TestEPA Sep 21, 2026