BRYANT HEATING AND COOLING SYSTEMS / AIR-SOURCE HEAT PUMP

284ANV036*0**B*

EVOLUTION Extreme 24 HP · EPA record 4529482

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4529482. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh18.00
EER2 · BTU/Wh10.50
HSPF2 · BTU/Wh9.00
Cooling capacity · BTU/h32000
Heating capacity at 47°F / 8.3°C · BTU/h35600
Heating capacity at 17°F / −8.3°C · BTU/h32600
Heating capacity at 5°F / −15°C · BTU/h26800
COP at 5°F / −15°C1.75
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-410A (GWP:2088)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unit284ANV036*0**B*
+
Indoor unitCAP**3617AL*+UI
+
Required furnace987TA48080C17***

AHRI reference 217106203 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for 284ANV036*0**B*

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4529482EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.75EPA Sep 21, 2026
eer2 btu wh10.50EPA Sep 21, 2026
series nameEVOLUTION Extreme 24 HPEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.00EPA Sep 21, 2026
model number284ANV036*0**B*EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh18.00EPA Sep 21, 2026
date certified2026-02-27T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerCarrier CorporationEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model number987TA48080C17***EPA Sep 21, 2026
refrigerant with gwpR-410A (GWP:2088)EPA Sep 21, 2026
ahri reference number217106203EPA Sep 21, 2026
cooling capacity btu h32000EPA Sep 21, 2026
outdoor unit brand nameBRYANT HEATING AND COOLING SYSTEMSEPA Sep 21, 2026
date available on market2021-02-15T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCAP**3617AL*+UIEPA Sep 21, 2026
energy star model identifierES_1020846_284ANV036*0**B*_03052025023025_28217106203EPA Sep 21, 2026
heating capacity at 5 f btu h26800EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h32600EPA Sep 21, 2026
heating capacity at 47 f btu h35600EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026