ECOER / AIR-SOURCE HEAT PUMP
EODA17H-4860AD*
TDi Select 2 · EPA record 4515805
Source checked Sep 21, 2026
Performance & equipment details
Values below belong to EPA record 4515805. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 17.00 |
| EER2 · BTU/Wh | 10.00 |
| HSPF2 · BTU/Wh | 8.80 |
| Cooling capacity · BTU/h | 55000 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56000 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 44000 |
| Heating capacity at 5°F / −15°C · BTU/h | 39500 |
| COP at 5°F / −15°C | 1.90 |
| Equipment / loop type | HP - Split System |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) |
| Compressor staging | Continuously variable |
| Connected capability | No |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+EODA17H-4860AD*Indoor unit
EAHDEN-60BE*AHRI reference 218004220 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for EODA17H-4860AD* →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 4515805 | EPA Sep 21, 2026 |
| markets | United States, Canada | EPA Sep 21, 2026 |
| cop at 5 f | 1.90 | EPA Sep 21, 2026 |
| eer2 btu wh | 10.00 | EPA Sep 21, 2026 |
| series name | TDi Select 2 | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 8.80 | EPA Sep 21, 2026 |
| model number | EODA17H-4860AD* | EPA Sep 21, 2026 |
| product type | HP - Split System | EPA Sep 21, 2026 |
| seer2 btu wh | 17.00 | EPA Sep 21, 2026 |
| date certified | 2025-11-24T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Continuously variable | EPA Sep 21, 2026 |
| energy star partner | Ecoer Inc. | EPA Sep 21, 2026 |
| connected capability | No | EPA Sep 21, 2026 |
| refrigerant with gwp | R-32 (GWP:675 | Lower GWP) | EPA Sep 21, 2026 |
| ahri reference number | 218004220 | EPA Sep 21, 2026 |
| cooling capacity btu h | 55000 | EPA Sep 21, 2026 |
| outdoor unit brand name | ECOER | EPA Sep 21, 2026 |
| date available on market | 2025-07-13T00:00:00.000 | EPA Sep 21, 2026 |
| indoor unit model number | EAHDEN-60BE* | EPA Sep 21, 2026 |
| energy star model identifier | ES_1141089_EODA17H-4860AD*_11232025223016_28218004220 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 39500 | EPA Sep 21, 2026 |
| meets most efficient criteria | Yes | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 44000 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 56000 | EPA Sep 21, 2026 |
| meets peak cooling requirements | No | EPA Sep 21, 2026 |
| controls verification procedure cvp test | ENERGY STAR CVP Test | EPA Sep 21, 2026 |