Metric or attributeSource value
SEER2 · BTU/Wh15.20
EER2 · BTU/Wh10.60
HSPF2 · BTU/Wh8.50
Cooling capacity · BTU/h24000
Heating capacity at 47°F / 8.3°C · BTU/h24000
Heating capacity at 17°F / −8.3°C · BTU/h20000
Heating capacity at 5°F / −15°C · BTU/h17000
COP at 5°F / −15°C1.80
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityYes

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitBOVB-24RTB-M15S
+
Indoor unitBIVA-24RXB-M15X

AHRI reference 217895296 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for BOVB-24RTB-M15S

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4512129EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.80EPA Sep 21, 2026
dr protocolOpenADREPA Sep 21, 2026
eer2 btu wh10.60EPA Sep 21, 2026
series nameIDS Light-LGWPEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh8.50EPA Sep 21, 2026
model numberBOVB-24RTB-M15SEPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh15.20EPA Sep 21, 2026
connects usingOther,LTEEPA Sep 21, 2026
date certified2025-10-17T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerBosch Thermotechnology CorporationEPA Sep 21, 2026
connected capabilityYesEPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number217895296EPA Sep 21, 2026
cooling capacity btu h24000EPA Sep 21, 2026
outdoor unit brand nameBoschEPA Sep 21, 2026
date available on market2025-10-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberBIVA-24RXB-M15XEPA Sep 21, 2026
energy star model identifierES_16809_BOVB-24RTB-M15S_10132025213040_28217895296EPA Sep 21, 2026
heating capacity at 5 f btu h17000EPA Sep 21, 2026
meets most efficient criteriaNoEPA Sep 21, 2026
heating capacity at 17 f btu h20000EPA Sep 21, 2026
heating capacity at 47 f btu h24000EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
communication hardware architectureA - Built-inEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026
broadband connection needed for demand responseYesEPA Sep 21, 2026