Ephoca / AIR-SOURCE HEAT PUMP
ADE09N4H2
AIO D Series · EPA record 4498742
Source checked Sep 21, 2026
Performance & equipment details
Values below belong to EPA record 4498742. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.
| Metric or attribute | Source value |
|---|---|
| SEER2 · BTU/Wh | 15.30 |
| EER2 · BTU/Wh | 11.56 |
| HSPF2 · BTU/Wh | 9.20 |
| Cooling capacity · BTU/h | 6100 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 8200 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 7800 |
| Heating capacity at 5°F / −15°C · BTU/h | 5900 |
| COP at 5°F / −15°C | 1.75 |
| Equipment / loop type | HP - Single Package |
| Refrigerant / source-reported GWP | R-32 (GWP:675 | Lower GWP) |
| Compressor staging | Continuously variable |
| Connected capability | Yes |
This listed system
These ratings apply to the listed configuration. Changing a component may change performance.
Outdoor unit
+ADE09N4H2Indoor unit
Integrated single packageAHRI reference 217652222 · reported by ENERGY STAR; no direct AHRI data connection.
All source records for ADE09N4H2 →Specifications & provenance
Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.
| Source field | Reported value | Evidence |
|---|---|---|
| pd id | 4498742 | EPA Sep 21, 2026 |
| markets | United States, Canada | EPA Sep 21, 2026 |
| cop at 5 f | 1.75 | EPA Sep 21, 2026 |
| dr protocol | CTA-2045,OpenADR | EPA Sep 21, 2026 |
| eer2 btu wh | 11.56 | EPA Sep 21, 2026 |
| series name | AIO D Series | EPA Sep 21, 2026 |
| cold climate | Yes | EPA Sep 21, 2026 |
| hspf2 btu wh | 9.20 | EPA Sep 21, 2026 |
| model number | ADE09N4H2 | EPA Sep 21, 2026 |
| product type | HP - Single Package | EPA Sep 21, 2026 |
| seer2 btu wh | 15.30 | EPA Sep 21, 2026 |
| connects using | Other,Wi-Fi,Modbus; BACnet; 3rd party thermostat control | EPA Sep 21, 2026 |
| date certified | 2026-06-04T00:00:00.000 | EPA Sep 21, 2026 |
| manufacturer type | System Manufacturer | EPA Sep 21, 2026 |
| compressor staging | Continuously variable | EPA Sep 21, 2026 |
| energy star partner | Ephoca, Inc | EPA Sep 21, 2026 |
| connected capability | Yes | EPA Sep 21, 2026 |
| refrigerant with gwp | R-32 (GWP:675 | Lower GWP) | EPA Sep 21, 2026 |
| ahri reference number | 217652222 | EPA Sep 21, 2026 |
| cooling capacity btu h | 6100 | EPA Sep 21, 2026 |
| outdoor unit brand name | Ephoca | EPA Sep 21, 2026 |
| date available on market | 2025-08-11T00:00:00.000 | EPA Sep 21, 2026 |
| energy star model identifier | ES_1152112_ADE09N4H2_08132025013020_28217652222 | EPA Sep 21, 2026 |
| heating capacity at 5 f btu h | 5900 | EPA Sep 21, 2026 |
| meets most efficient criteria | Yes | EPA Sep 21, 2026 |
| heating capacity at 17 f btu h | 7800 | EPA Sep 21, 2026 |
| heating capacity at 47 f btu h | 8200 | EPA Sep 21, 2026 |
| meets peak cooling requirements | No | EPA Sep 21, 2026 |
| communication hardware architecture | B - Manufacturer-specific external communication module(s) and/or device(s) | EPA Sep 21, 2026 |
| controls verification procedure cvp test | DOE Federal CVP Test,ENERGY STAR CVP Test | EPA Sep 21, 2026 |
| primary communication module device brand name | Wi-Fi communication chip installed on manufacturer-specific Gateway Board (MOD TPG/GWB20 or GWX/GWN) for remote monitoring and control | EPA Sep 21, 2026 |
| broadband connection needed for demand response | No | EPA Sep 21, 2026 |
| features enabled by primary communication module | User amenity (e.g. real time power reporting, remote management, user settings and messages) | EPA Sep 21, 2026 |
| primary communication module device model number | Wi-Fi Chip for MOD TPG/GWB20 or GWX/GWN Gateway Board | EPA Sep 21, 2026 |