AC PRO / AIR-SOURCE HEAT PUMP

AUD60W/A1-D(U)

X Series · EPA record 4498175

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4498175. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh17.00
EER2 · BTU/Wh11.00
HSPF2 · BTU/Wh9.00
Cooling capacity · BTU/h48000
Heating capacity at 47°F / 8.3°C · BTU/h48000
Heating capacity at 17°F / −8.3°C · BTU/h39500
Heating capacity at 5°F / −15°C · BTU/h39000
COP at 5°F / −15°C1.80
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-410A (GWP:2088)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitAUD60W/A1-D(U)
+
Indoor unitAUD48AH2/A1-D(U)

AHRI reference 217656847 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for AUD60W/A1-D(U)

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4498175EPA Sep 21, 2026
marketsUnited States, CanadaEPA Sep 21, 2026
cop at 5 f1.80EPA Sep 21, 2026
eer2 btu wh11.00EPA Sep 21, 2026
series nameX SeriesEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.00EPA Sep 21, 2026
model numberAUD60W/A1-D(U)EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh17.00EPA Sep 21, 2026
date certified2026-07-07T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerMaterial Supply Inc. dba AC ProEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
refrigerant with gwpR-410A (GWP:2088)EPA Sep 21, 2026
ahri reference number217656847EPA Sep 21, 2026
cooling capacity btu h48000EPA Sep 21, 2026
outdoor unit brand nameAC PROEPA Sep 21, 2026
date available on market2023-01-01T00:00:00.000EPA Sep 21, 2026
indoor unit model numberAUD48AH2/A1-D(U)EPA Sep 21, 2026
installation capabilitiesNoneEPA Sep 21, 2026
energy star model identifierES_1146622_AUD60W/A1-D(U)_08152025053011_28217656847EPA Sep 21, 2026
heating capacity at 5 f btu h39000EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h39500EPA Sep 21, 2026
heating capacity at 47 f btu h48000EPA Sep 21, 2026
meets peak cooling requirementsNoEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026