Hitachi / AIR-SOURCE HEAT PUMP

RAM-G24N3HAA

airHome Multi · EPA record 4479325

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4479325. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh20.00
EER2 · BTU/Wh12.10
HSPF2 · BTU/Wh9.50
Cooling capacity · BTU/h24000
Heating capacity at 47°F / 8.3°C · BTU/h24000
Heating capacity at 17°F / −8.3°C · BTU/h16000
Heating capacity at 5°F / −15°C · BTU/h18200
COP at 5°F / −15°C2.20
Equipment / loop typeHP - Mini or Multi Split
Refrigerant / source-reported GWPR-32 (GWP:675 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

Outdoor-model source rating

EPA reports this outdoor model and its ratings without listing individual indoor units. A complete matched configuration is not available in this record. Do not infer compatibility with a particular indoor unit.

EPA multi-split reporting rules ↗

Outdoor unitRAM-G24N3HAA
+
Indoor unitIndoor configuration not listed by EPA

AHRI reference 217549984 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for RAM-G24N3HAA

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4479325EPA Sep 21, 2026
marketsUnited StatesEPA Sep 21, 2026
cop at 5 f2.20EPA Sep 21, 2026
eer2 btu wh12.10EPA Sep 21, 2026
series nameairHome MultiEPA Sep 21, 2026
cold climateYesEPA Sep 21, 2026
hspf2 btu wh9.50EPA Sep 21, 2026
model numberRAM-G24N3HAAEPA Sep 21, 2026
product typeHP - Mini or Multi SplitEPA Sep 21, 2026
seer2 btu wh20.00EPA Sep 21, 2026
date certified2026-01-14T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerJohnson Controls, Inc.EPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
refrigerant with gwpR-32 (GWP:675 | Lower GWP)EPA Sep 21, 2026
ahri reference number217549984EPA Sep 21, 2026
cooling capacity btu h24000EPA Sep 21, 2026
indoor unit brand nameHitachiEPA Sep 21, 2026
outdoor unit brand nameHitachiEPA Sep 21, 2026
date available on market2024-11-22T00:00:00.000EPA Sep 21, 2026
energy star model identifierES_21045_RAM-G24N3HAA_06272025011737_29217549984EPA Sep 21, 2026
heating capacity at 5 f btu h18200EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h16000EPA Sep 21, 2026
heating capacity at 47 f btu h24000EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testENERGY STAR CVP TestEPA Sep 21, 2026