Lennox / AIR-SOURCE HEAT PUMP

EL21KLV-060-230A**

Elite EL21KLV SERIES · EPA record 4006588

Source checked Sep 21, 2026

Performance & equipment details

Values below belong to EPA record 4006588. Temperature points and test metrics are preserved as reported. Missing and zero values are not substituted with estimates.

Metric or attributeSource value
SEER2 · BTU/Wh19.50
EER2 · BTU/Wh11.50
HSPF2 · BTU/Wh8.50
Cooling capacity · BTU/h55500
Heating capacity at 47°F / 8.3°C · BTU/h53500
Heating capacity at 17°F / −8.3°C · BTU/h44000
Heating capacity at 5°F / −15°C · BTU/h35000
COP at 5°F / −15°C2.14
Equipment / loop typeHP - Split System
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)
Compressor stagingContinuously variable
Connected capabilityNo

Open original source record ↗

This listed system

These ratings apply to the listed configuration. Changing a component may change performance.

Outdoor unitEL21KLV-060-230A**
+
Indoor unitCK40[C,U]T-60C-**+TDR
+
Required furnaceEL180UH100NE60C*

AHRI reference 217121507 · reported by ENERGY STAR; no direct AHRI data connection.

All source records for EL21KLV-060-230A**

Specifications & provenance

Every value below is preserved from the source record. Checked Sep 21, 2026. Asterisks and other model wildcards are retained as published.

Source fieldReported valueEvidence
pd id4006588EPA Sep 21, 2026
marketsUnited StatesEPA Sep 21, 2026
cop at 5 f2.14EPA Sep 21, 2026
eer2 btu wh11.50EPA Sep 21, 2026
series nameElite EL21KLV SERIESEPA Sep 21, 2026
cold climateNoEPA Sep 21, 2026
hspf2 btu wh8.50EPA Sep 21, 2026
model numberEL21KLV-060-230A**EPA Sep 21, 2026
product typeHP - Split SystemEPA Sep 21, 2026
seer2 btu wh19.50EPA Sep 21, 2026
date certified2025-10-27T00:00:00.000EPA Sep 21, 2026
manufacturer typeSystem ManufacturerEPA Sep 21, 2026
compressor stagingContinuously variableEPA Sep 21, 2026
energy star partnerLennox IndustriesEPA Sep 21, 2026
connected capabilityNoEPA Sep 21, 2026
furnace model numberEL180UH100NE60C*EPA Sep 21, 2026
refrigerant with gwpR-454B (GWP:470 | Lower GWP)EPA Sep 21, 2026
ahri reference number217121507EPA Sep 21, 2026
cooling capacity btu h55500EPA Sep 21, 2026
outdoor unit brand nameLennoxEPA Sep 21, 2026
date available on market2025-04-04T00:00:00.000EPA Sep 21, 2026
indoor unit model numberCK40[C,U]T-60C-**+TDREPA Sep 21, 2026
installation capabilitiesAutomatic system discovery,Test mode for manual measurements,Preprogrammed system testsEPA Sep 21, 2026
energy star model identifierES_1082495_EL21KLV-060-230A**_03252025153021_28217121507EPA Sep 21, 2026
heating capacity at 5 f btu h35000EPA Sep 21, 2026
meets most efficient criteriaYesEPA Sep 21, 2026
heating capacity at 17 f btu h44000EPA Sep 21, 2026
heating capacity at 47 f btu h53500EPA Sep 21, 2026
meets peak cooling requirementsYesEPA Sep 21, 2026
controls verification procedure cvp testDOE Federal CVP TestEPA Sep 21, 2026